3. INSTALLATION Press the tab. 1843B Connector Machine head memory 7-pin Upper shaft motor 3-pin Synchronizer 14-pin Connector Work clamp pulse motor 4-pin black Thread trimmer solenoid 6-pin Tension release solenoid 4-pin Y pulse motor 4-pin blue X pulse motor 4-pin white NOTE: Route the X, Y and work clamp pulse motor harnesses so that they do not touch the PMD P.C. *1 : Be sure to make the ground connection. (Refer to "3-9. Connecting the ground wire".) Connection location on power supply motor P.C. board P3 (HEAD-M) P4 (UVW) P5 (SYNC) Connection location on PMD P.C. board P3 (PPM) P6 (SOL1) P7 (SOL2) P8 (YPM) P10 (XPM) Cord clamp/cable tie (4) (5) (5), (6) Cable tie (5), (6) (5), (6) (5), (6) (5), (6) (5), (6) (Continued on next page) BAS-326G PS 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

3. INSTALLATION
BAS-326G PS
12
<Power supply motor P.C. board>
<PMD P.C. board>
Connector
Connection location on
power supply motor P.C.
board
Cord clamp/cable tie
Machine head memory 7-pin
P3 (HEAD-M)
(4)
Upper shaft motor 3-pin
P4 (UVW)
(5)
Synchronizer 14-pin
P5 (SYNC)
(5), (6)
Connector
Connection location on
PMD P.C. board
Cable tie
Work clamp pulse motor 4-pin black
P3 (PPM)
(5), (6)
Thread trimmer solenoid 6-pin
P6 (SOL1)
(5), (6)
Tension release solenoid 4-pin
P7 (SOL2)
(5), (6)
Y pulse motor 4-pin blue
P8 (YPM)
(5), (6)
X pulse motor 4-pin white
P10 (XPM)
(5), (6)
(Continued on next page)
<Removing>
Press
the tab.
<Securing>
1843B
NOTE:
Route the X, Y and work clamp pulse motor
harnesses so that they do not touch the
PMD P.C.
*
1
:
Be sure to make the ground connection.
(Refer to "3-9. Connecting the ground
wire".)