Canon EOS50D EOS 50D Instruction Manual - Page 119

Dust Delete Data, Sensor cleaning, Clear settings, Firmware Ver., Battery Life with Live View

Page 119 highlights

ShootingN Pressing the button will display the menu screen so you can set menu functions. Press the button again to return to the Live View image. If you select [2 Dust Delete Data], [6 Sensor cleaning], [7 Clear settings], or [7 Firmware Ver.], the Live View shooting will be terminated. Battery Life with Live View Shooting [Approx. number of shots] Temperature At 23°C / 73°F At 0°C / 32°F Shooting Conditions No Flash 50% Flash Use 180 170 140 130 The figures above are based on a fully-charged Battery Pack BP-511A and CIPA (Camera & Imaging Products Association) testing standards. Continuous Live View shooting is possible for about 1 hours at 23°C/73°F (with fully-charged BP-511A). Using AF will decrease the number of possible shots. The image's field of view is about 100%. If the camera is not operated for a prolonged period, the power will turn off automatically as set with [5 Auto power off] (p.44). If [5 Auto power off] is set to [Off], the Live View shooting will stop automatically after 30 min. (camera power remains on). A grid can be displayed. With the [6 Live View function settings] menu's [Grid display], you can set either [Grid 1 ] or [Grid 2 ]. With the [6 Live View function settings] menu's [Metering timer], you can change how long the AE lock's setting is to be retained. When you take a picture with flash, the shutter will sound like it took two shots. However, only one shot will be taken. With the video cable (provided) or HDMI cable (sold separately), you can display the Live View image on a TV (p.141-142). 119

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228

119
Shooting
N
Pressing the <
M
> button will display the menu screen so you
can set menu functions. Press the <
M
> button again to return
to the Live View image. If you select [
2
Dust Delete Data
], [
6
Sensor cleaning
], [
7
Clear settings
], or [
7
Firmware Ver.
], the
Live View shooting will be terminated.
Battery Life with Live View Shooting
[Approx. number of shots]
The figures above are based on a fully-charged Battery Pack BP-511A and
CIPA (Camera & Imaging Products Association) testing standards.
Continuous Live View shooting is possible for about 1 hours at 23°C/73°F (with
fully-charged BP-511A).
Using AF will decrease the number of possible shots.
Temperature
Shooting Conditions
No Flash
50% Flash Use
At 23°C / 73°F
180
170
At 0°C / 32°F
140
130
The image’s field of view is about 100%.
If the camera is not operated for a prolonged period, the power will turn
off automatically as set with [
5
Auto power off
] (p.44). If [
5
Auto
power off
] is set to [
Off
], the Live View shooting will stop automatically
after 30 min. (camera power remains on).
A grid can be displayed. With the [
6
Live View function settings
]
menu’s [
Grid display
], you can set either [
Grid 1
] or [
Grid 2
].
With the [
6
Live View function settings
] menu’s [
Metering timer
], you
can change how long the AE lock’s setting is to be retained.
When you take a picture with flash, the shutter will sound like it took two
shots. However, only one shot will be taken.
With the video cable (provided) or HDMI cable (sold separately), you can
display the Live View image on a TV (p.141-142).