Dell 2355DN Service Manual - Page 98
Fuser Error, Less than 10W?
View all Dell 2355DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Fuser Error Alignment and Troubleshooting Measure the resistance at the both ends of AC(Con no.2 of the SMPS board) Line with covers open Less than 10W? YES Remove the covers NO Thermostat is open due to the heat etc. -> Replace the thermostat Check CN26 of the main board. NO Is the conector inserted right ways? YES Re-assemble the connector. Check CN23 of the main board. NO Is the conector inserted right ways? Re-assemble the connector. Fuser Error eliminated? YES END Replace the main board. 4-58 Service Manual
Alignment and Troubleshooting
4-58
Service Manual
Fuser Error
Replace the main board.
Check CN23 of the main board.
Is the conector inserted
right ways?
Fuser Error eliminated?
END
Thermostat is open due to the heat etc.
-> Replace the thermostat
Measure the resistance at the both ends
of AC(Con no.2 of the SMPS board)
Line with covers open
Remove the covers
NO
NO
NO
YES
YES
YES
Check CN26 of the main board.
Is the conector inserted
right ways?
Re-assemble the connector.
Re-assemble the connector.
Less than 10W?