Before you call for service... Troubleshooting Tips Save time and mone_l! Review the charts on the following pages first and _lOUm%l not need to call for ervice. Problem Zoneline does not start Possible Causes The unit is unplugged, The power cord is not firmly attached, The fuse is blown/circuit breaker is tripped, The unit is waiting for the compressoroverload protector to reset. Power failure. The current interrupter device is tripped. What To Do • Hake sure the Zoneline plug is pushed completely into the outlet. • Removethe room cabinet and make sure that the yellow connector on the end of the power cord is firmly engaged. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. • This is normal. The Zoneline will start again after it resets. • If power failure occurs, set the mode control to STOP. When power is restored, set the mode control to the desired setting. • There is a protective time delay (up to 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal heating or cooling for 3 minutes after it is turned back on. • Pressthe REgETbutton located on the power cord plug or the box near the plug. • If the RESETbutton will not stay engaged, discontinue use of the Zonelineand contact a qualified servicetechnician. Zonefine does not cool or heat as it should Indoor airflow is restricted, Outdoor airflow is restricted or recirculated. The temp control mag not be set properlg. The air filter is dirty. The room may have been hot or cold. Outdoor air is entering the room. • Hake sure there are no curtains, blinds or furniture blocking the front of the Zoneline. • Hake sure the rear grille is not restricted.This can cause the unit to cycle off due to the compressor overload protector. • Outdoor grille must have a minimum of 65% free area. Non-GEgrilles may be too restrictive for proper performance. Consult your salesperson for assistance. • Turn the control to a lower or higher setting. NOTE: The temperature limiter may be limiting the temperature range. • Clean the filter at least every 30 days. See the Operating Instructions section. • When the Zoneline is first turned on you need to allow time for the room to cool down or warm up. • Set the vent control to the closed position. Burning odorat thestart Dust is on the surface of heating operation of the heating element. • This can cause a "burning" odor at the beginning of the heating operation. This odor should quickly fade. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Before
you
call
for
service...
Troubleshooting Tips
Save
time and mone_l! Review
the charts
on
the
following pages first and _lOUm%l not need
to
call
for
ervice.
Problem
Possible
Causes
What
To Do
Zoneline
does
The unit is
• Hake sure the Zoneline plug is pushed completely
not
start
unplugged,
into the outlet.
The power cord is not
• Removethe room cabinet and make sure that the
firmly attached,
yellow connector on the end of the power cord is
firmly engaged.
The fuse is blown/circuit
• Check the house fuse/circuit breaker box and replace
breaker is tripped,
the fuse or reset the breaker.
The unit is waiting for
• This is normal. The Zoneline will start again after
the
compressor
overload
it resets.
protector to reset.
Power failure.
• If power failure occurs, set the mode control to STOP.
When power is restored, set the mode control to the
desired setting.
• There is a protective time delay (up to 3 minutes) to
prevent tripping of the compressor overload. For this
reason, the unit may not start normal heating or cooling
for 3 minutes after it is turned back on.
The
current interrupter
device is tripped.
• Pressthe
REgETbutton
located on the power cord plug
or the box near the plug.
• Ifthe
RESET
button will not stay engaged, discontinue use
of the Zonelineand contact a qualified servicetechnician.
Zonefine does not cool
Indoor airflow
• Hake sure there are no curtains, blinds or furniture
or
heat
as
it
should
is restricted,
blocking the front of the Zoneline.
Burning
odor
at the
start
of heating operation
Outdoor airflow is
restricted or recirculated.
• Hake sure the rear grille is not restricted.This can
cause the unit to cycle off due to the compressor
overload protector.
• Outdoor grille must have a minimum of 65% free area.
Non-GEgrilles may be too restrictive for proper
performance. Consult your salesperson for assistance.
The temp
control
mag
• Turn the control
to a lower or higher setting.
not be
set
properlg.
NOTE: The temperature
limiter may be limiting the
temperature
range.
The air filter
is dirty.
• Clean the filter at least every 30 days.
See the
Operating
Instructions
section.
The room
may
have
• When the Zoneline is first turned
on you need to
been hot or cold.
allow time for the room to cool down
or warm
up.
Outdoor
air is
• Set the vent control to the closed position.
entering
the
room.
Dust
is
on the
surface
of the
heating
element.
• This can cause a "burning" odor at the beginning of
the heating operation. This odor should quickly fade.
20