GE AZ61H12DAB Owners Manual - Page 3
controls, Zoneline. - model
View all GE AZ61H12DAB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
About the controls on your Zoneline. in HiGH _"COOL ! LOW ! FAN AUTO _ HEAT m GEApUionces.com ! TEMP FAN MODE SLEEP OPERATION TEMP CONTROL FAN,MODE& SLEEPOPERATION 0 @ Controls TThaemtepmCp coonntrtrooll is usedto maintain the room temperature.Thecompressorwill cycle on and off to keepthe room at the same level of comfort. Pressthe _ pad to raisethe temperature. Pressthe V pad to lowerthe temperature. NOTET: he displayshows the set temperature, not the room temperature. SPlreeesspto set the air conditionerto run for 8 hours before it automatically returnsto the previous setting. When in the cooling mode and the sleeptimer is set,the set temperature will automatically increase2°Fafter the second hour then I°F each hour overthe next two hours.Also,the fan speedwill changeto low. When in the heating mode, the set temperature will decreasein the same manner. Tocancel the sleep mode,pressthe MODEpad or the SLEEPpad a second time. @Fan, Mode and Operation Control FAN--Setsthe fan operationfor HIGH, LOWor AUTO speed.When set at AUTO, it automatically switches between LOW and HIGHas room temperature changes. MODE--COOL--For cooling FAN--For fan-only operation HEAT--For heating OPERATION--ON/STOP--Turtnhse unit on or off. Powerremains connectedto the Zoneline.The Freeze/HeatSentinel features still function if active.Seethe Freezer/HeaSt entinelsection on page 6. NOTET: hetemperaturedisplo_jwill flash to indicate o possibleunit malfunction.Set operation control to STOPand then restart the unit. If the flashing light reappears within 30 minutes, coil for service. Quick Heat Recovery Activateseach time the thermostat isswitched from STOPor COOLmode to HEATmode. Electricheaters are energizeduntil the thermostat set point is reached.On heat pump models,the heat pump operationwill resumeat the next call for heat. About Your Heat Pump (6100 Series only) Heat pumps can save money by removing heat from the outside air-even when the outside temperature is below freezing-and releasing that heat indoors. To get the best performance from your heat pump, don't change the room thermostat very often. Raising the heat setting 2-5 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperature setting quickly. There is a 5-minute minimum compressor run time at any setting to prevent short cycling. The indoor fan motor starts before the compressor and stops after the compressor cycles off. When the outdoor temperature is lower than 25°F, heat is provided by the electric heater in the air conditioner instead of by the heat pump. The electric heating elements use much more electricity than heat pumps and cost more to operate. 3