Hayward HL32950VSP VS Omni Residential Troubleshooting Guide - Page 46

VAC

Page 46 highlights

7. CL lights (14v): Out-of-Sync Low voltage lighting should be powered off the 14 volt circuit of the transformer, if multiple taps are included in the transformer, verify they are connect to the 14v tap. Service Mode & Toggle Lights Step 7C Test Transformer Output Step 7D 14VAC Put system in service mode (power>service mode), then toggle lights on, off, & back on. IF lights are illuminating, install a snubber & resync lights after exiting service. IF they did not illuminate, go to 7D. Open lighting transformer and test for 14vAC on the output side. IF voltage is correct on the output side of the transformer, replace defective lights. IF no/low voltage, go to step 7E. 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

46
Low voltage lighting should be powered off the 14 volt circuit of the transformer, if
multiple taps are included in the transformer, verify they are connect to the 14v tap.
Put system in service mode (power>service mode),
then toggle lights on, off, & back on. IF lights are
illuminating, install a snubber & resync lights after
exiting service. IF they did not illuminate, go to 7D.
Open lighting transformer and test for 14vAC on the
output side. IF voltage is correct on the output side of
the transformer, replace defective lights. IF no/low
voltage, go to step 7E.
Service Mode & Toggle Lights
Step 7C
Step 7D
Test Transformer Output
7. CL lights (14v): Out-of-Sync
14VAC