HP 2000sa HP Direct-Connect External SAS Storage for HP BladeSystem Solutions - Page 82
The following standards are maintained in the sample configurations, Dual domain, Single domain
View all HP 2000sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
The following standards are maintained in the sample configurations: Device SAS switches: MSA2000sa SAS controller modules: MDS600 SAS I/O modules: Cabling: Zoning: Single domain Dual domain Depending on the type of server blade used, one or two switches are installed in the c-Class enclosure, providing a single path between the server blades and the switches. nl When using full-height or half-height server blades, one switch is required. nl When using double-density server blades in the c7000 enclosure, two switches are required, installed in different interconnect rows, for example, in interconnect bays 5 and 7. Depending on the type of server blade used, two or four switches are installed in the c-Class enclosure, providing dual paths between the server blades and the switches. nl When using full-height or half-height server blades, two switches are required, installed in adjacent interconnect bays, for example, in interconnect bays 5 and 6. nl When using double-density server blades in the c7000 enclosure, four switches are required, installed in different interconnect rows, for example, in interconnect bays 5, 6, 7, and 8. One controller is installed in MSA2000sa Two controllers are installed in controller enclosures, providing a single MSA2000sa controller enclosures, path between the switch and the providing an alternate path between the MSA2000sa. switches and the MSA2000sa. Two I/O modules are installed in the MDS600 storage enclosure, providing a single path between the switch and the single-port SATA drives in each MDS600 enclosure drawer. Four I/O modules are installed in the MDS600 storage enclosure, providing alternate paths between the switches and the dual-port SAS drives in each MDS600 enclosure drawer. A single cable is connected between the Two cables are connected between the switch and the storage enclosure. If ports switch and the storage enclosure: one from on the switch and the storage enclosure the primary controller or I/O module and are available, connect an additional cable one from the secondary controller or I/O between the devices, for improved module. If ports on the switch and the performance. storage enclosure are available, connect an additional cable between the devices, for improved performance. When creating and assigning zone groups to server bays, assign server bays 1-8 to zone groups associated with storage connected to switch ports 1, 2, 3, or 4. Assign server bays 9-16 to zone groups associated with storage connected to switch ports 5, 6, 7, or 8. For more information, see "Zoning requirements and device mappings" (page 39). 82 Introduction