HP 8/8 Fabric OS Encryption Administrator's Guide v6.4.0 (53-1001864-01, June - Page 101

Consequences of removing an encryption switch, TABLE 2

Page 101 highlights

Viewing and editing group properties 2 Consequences of removing an encryption switch Table 2 explains the impact of removing switches. TABLE 2 Switch removal impact Switch configuration Impact of removal The switch is the only switch in the encryption group. The switch has configured encryption targets on encryption engines. The encryption group is also removed. • The switch is configured to encrypt traffic to one or more encryption targets. • The target container configuration is removed. • The encrypted data remains on the encryption target but is not usable until the encryption target is manually configured on another encryption switch. The switch has encryption engines in HA Clusters. CAUTION The encryption target data is visible in encrypted format to zoned hosts. It is strongly recommended that you remove the encryption targets from all zones before you disable encryption. Otherwise, hosts may corrupt the encrypted data by writing directly to the encryption target without encryption. The HA Clusters are removed. High availability is no longer provided to the other encryption engine in each HA Cluster. Figure 48 shows the warning message that displays if you click Remove to remove a switch. FIGURE 48 Removal of switch warning Fabric OS Encryption Administrator's Guide 83 53-1001864-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248

Fabric OS Encryption Administrator’s Guide
83
53-1001864-01
Viewing and editing group properties
2
Consequences of removing an encryption switch
Table 2
explains the impact of removing switches.
Figure 48
shows the warning message that displays if you click
Remove
to remove a switch.
FIGURE 48
Removal of switch warning
TABLE 2
Switch removal impact
Switch configuration
Impact of removal
The switch is the only switch in the encryption
group.
The encryption group is also removed.
The switch has configured encryption targets on
encryption engines.
The switch is configured to encrypt traffic to one or more
encryption targets.
The target container configuration is removed.
The encrypted data remains on the encryption target but
is not usable until the encryption target is manually
configured on another encryption switch.
CAUTION
The encryption target data is visible in
encrypted format to zoned hosts. It is
strongly recommended that you remove the
encryption targets from all zones before you
disable encryption. Otherwise, hosts may
corrupt the encrypted data by writing
directly to the encryption target without
encryption.
The switch has encryption engines in HA
Clusters.
The HA Clusters are removed. High availability is no longer
provided to the other encryption engine in each HA Cluster.