HP 8/8 Fabric OS Encryption Administrator's Guide v6.4.0 (53-1001864-01, June - Page 172

Single fabric deployment - DEK cluster,

Page 172 highlights

4 Single fabric deployment - DEK cluster In Figure 59, the two encryption switches provide a redundant encryption path to the target devices. The encryption switches are interconnected through a dedicated cluster LAN. The Ge1 and Ge0 gigabit Ethernet ports on each of these switches are attached to this LAN. This LAN connection provides the communication needed to distribute and synchronize configuration information, and enable the two switches to act as a high availability (HA) cluster, providing automatic failover if one of the switches fails, or is taken out of service. Single fabric deployment - DEK cluster Figure 60 shows an encryption deployment in a single fabric with two paths between a host and a target.device. . FIGURE 60 Single fabric deployment - DEK cluster 154 Fabric OS Encryption Administrator's Guide 53-1001864-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248

154
Fabric OS Encryption Administrator’s Guide
53-1001864-01
Single fabric deployment - DEK cluster
4
In
Figure 59
, the two encryption switches provide a redundant encryption path to the target
devices. The encryption switches are interconnected through a dedicated cluster LAN. The Ge1 and
Ge0 gigabit Ethernet ports on each of these switches are attached to this LAN. This LAN connection
provides the communication needed to distribute and synchronize configuration information, and
enable the two switches to act as a high availability (HA) cluster, providing automatic failover if one
of the switches fails, or is taken out of service.
Single fabric deployment - DEK cluster
Figure 60
shows an encryption deployment in a single fabric with two paths between a host and a
target.device.
.
FIGURE 60
Single fabric deployment - DEK cluster