HP AD510A HP StorageWorks 1500 Modular Smart Array maintenance and service gui - Page 115

Class B equipment, Canadian compliance

Page 115 highlights

Index A AC circuit overload, warning, 67 accumulators, 112 ADU, described, 32 alkaline battery warning, 112 audience, 9 Avis Canadien, regulatory compliance notice, 110 B backplane, replacement, 92 batteries recycling or disposal, 112 replacement notice, 112 warning, 112 Taiwan EPA recycling and disposal, 113 warnings, 80 boot straps, using, 114 BSMI, regulatory compliance notice, 111 C cables distances supported, 13 FCC compliance statement, 110 multi-mode, 13 option kits, 13 part numbers, 13 shielded, 110 cache battery pack, replacing, 80 module, replacing, 80 Canada, regulatory compliance notice, 110 cautions thermal failure, 74 chassis replacement, 92 chassis specifications dimensions, 16 input voltage requirements, 16 maximum wet-bulb temperature, 16 relative humidity, 16 server temperature, 16 weight, 16 Class A equipment, Canadian compliance statement, 110 Class B equipment, Canadian compliance statement, 110 cloning of firmware between controllers, 71, 103 Command Line Interface, described, 32 component level repairs, warning, 67 controller display messages, 36 ejector levers, 79 failure, 78 latches, 79, 84 removing, 79 replacing, 78 securing, 84 controller display components, 35 error messages, 36 informational messages, 36 message types, 36 operating modes, 35 user input messages, 37 controller display messages access control conflict detected, 52 access control resources exceeded, 52 array controller disabled, 53 array controller overheated, 53 array controller overheating, 53 array controller restarting, 53 array controller temperature ok, 53 bad hard drive firmware box, 48 bad SCSI bus mode non-LVD device found, 40 bad scsi target, 40 beacon off, 53 beacon on, 52 cache batteries low, recharging, 46 cache data lost battery dead, 45 cache disabled no configuration, 46 cache error, 47 cache hardware batteries, 47 cache hardware enabled, 45 cache hardware failed and disabled, 45 cache hardware temporarily disabled, 46 cache module # MB, 45 chassis nvram contents corrupted, 41 clone firmware, 38 cloning refused system halted, 39 configured volumes, 51 controller too old not supported, 38 critical lockup detected, 37 dual cache module size mismatch, 45 EMU flash done, 55 EMU flash failed, 55 EMU flash started, 55 enable volume, 37 enable volumes, 38 fibre device hardware failure, 58 fibre subsystem hardware failure, 58 maintenance and service guide 115

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Index
A
AC
circuit overload, warning
, 67
accumulators
, 112
ADU, described
, 32
alkaline battery warning
, 112
audience
,9
Avis Canadien, regulatory compliance notice
,
110
B
backplane, replacement
, 92
batteries
recycling or disposal
, 112
replacement
notice
, 112
warning
, 112
Taiwan EPA recycling and disposal
, 113
warnings
, 80
boot straps, using
, 114
BSMI, regulatory compliance notice
, 111
C
cables
distances supported
, 13
FCC compliance statement
, 110
multi-mode
, 13
option kits
, 13
part numbers
, 13
shielded
, 110
cache
battery pack, replacing
, 80
module, replacing
, 80
Canada, regulatory compliance notice
, 110
cautions
thermal failure
, 74
chassis replacement
, 92
chassis speci
cations
dimensions
, 16
input voltage requirements
, 16
maximum wet-bulb temperature
, 16
relative humidity
, 16
server temperature
, 16
weight
, 16
Class A equipment, Canadian compliance
statement
, 110
Class B equipment, Canadian compliance
statement
, 110
cloning of
rmware between controllers
, 71,
103
Command Line Interface, described
, 32
component level repairs, warning
, 67
controller
display messages
, 36
ejector levers
, 79
failure
, 78
latches
, 79, 84
removing
, 79
replacing
, 78
securing
, 84
controller display
components
, 35
error messages
, 36
informational messages
, 36
message types
, 36
operating modes
, 35
user input messages
, 37
controller display messages
access control con
ict detected
, 52
access control resources exceeded
, 52
array controller disabled
, 53
array controller overheated
, 53
array controller overheating
, 53
array controller restarting
, 53
array controller temperature ok
, 53
bad hard drive
rmware box
, 48
bad SCSI bus mode non-LVD device found
,
40
bad scsi target
, 40
beacon off
, 53
beacon on
, 52
cache batteries low, recharging
, 46
cache data lost battery dead
, 45
cache disabled no con
guration
, 46
cache error
, 47
cache hardware batteries
, 47
cache hardware enabled
, 45
cache hardware failed and disabled
, 45
cache hardware temporarily disabled
, 46
cache module # MB
, 45
chassis nvram contents corrupted
, 41
clone
rmware
, 38
cloning refused system halted
, 39
con
gured volumes
, 51
controller too old not supported
, 38
critical lockup detected
, 37
dual cache module size mismatch
, 45
EMU
ash done
, 55
EMU
ash failed
, 55
EMU
ash started
, 55
enable volume
, 37
enable volumes
, 38
bre device hardware failure
, 58
bre subsystem hardware failure
, 58
maintenance and service guide
115