Storage Box, <n> Overheated

Page 56 highlights

Message 402 STORAGE BOX # FAN DEGRADED Type Error 403 STORAGE BOX # FAN HOT INSERTED 404 STORAGE BOX # FAN HOT REMOVED 405 STORAGE BOX # TEMPERATURE OK Informational Informational Informational 406 STORAGE BOX # OVERHEATING Error 407 STORAGE BOX # OVERHEATED Error 408 STORAGE BOX # POWER SUPPLY OK Informational 409 STORAGE BOX # POWER SUPPLY FAILED 410 STORAGE BOX # POWER SUPPLY ADDED 411 STORAGE BOX # POWER SUPPLY REMOVED Error Informational Informational Description Action A fan in the specified storage enclosure is not operating at full efficiency. The fan may eventually fail. Check all fans and ensure they are operating. Any failed fans should be replaced. An fan in the specified storage enclosure has been hot-added. A fan in the specified storage enclosure has been removed. The temperature in the specified storage enclosure is now back in the normal operating range. The temperature in the specified storage enclosure is starting to exceed the normal operating range. Check all fans and ensure they are operating. Any failed fans should be replaced. Ensure that there is a module or blanking panel (cover plate) in all MSA chassis bays and slots. Empty bays affect the airflow and cooling ability of the MSA. The temperature in the specified storage enclosure has exceeded the safe operating range. The MSA should be powered off as soon as possible and immediately after that, the enclosure should be powered off, to avoid hardware failure. Check all MSA fans and ensure they are operating. Any failed fan should be replaced. Ensure that there is a module or blanking panel (cover plate) in all MSA chassis bays and slots. Empty bays affect the airflow and cooling ability of the MSA. The power supply in the specified storage enclosure that was previously marked as failed or degraded is now operating normally. A power supply in the specified storage enclosure has failed. Check all power supplies and ensure they are operating. Any failed power supplies should be replaced. A power supply in the specified storage enclosure has been added. A power supply in the specified storage enclosure has been removed. 56 LCD panel and message descriptions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Message
Type
Description
Action
402 STORAGE BOX
#<n> FAN DEGRADED
Error
A fan in the speci
ed
storage enclosure is not
operating at full ef
ciency.
The fan may eventually fail.
Check all fans and ensure
they are operating. Any
failed fans should be
replaced.
403 STORAGE BOX
#<n> FAN HOT
INSERTED
Informational
An fan in the speci
ed
storage enclosure has been
hot-added.
404 STORAGE BOX
#<n> FAN HOT
REMOVED
Informational
A fan in the speci
ed
storage enclosure has been
removed.
405 STORAGE BOX
#<n> TEMPERATURE OK
Informational
The temperature in the
speci
ed storage enclosure
is now back in the normal
operating range.
406 STORAGE BOX
#<n> OVERHEATING
Error
The temperature in the
speci
ed storage enclosure
is starting to exceed the
normal operating range.
Check all fans and ensure
they are operating. Any
failed fans should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the air
ow
and cooling ability of the
MSA.
407 STORAGE BOX
#<n> OVERHEATED
Error
The temperature in the
speci
ed storage enclosure
has exceeded the safe
operating range.
The MSA should be powered
off as soon as possible
and immediately after
that, the enclosure should
be powered off, to avoid
hardware failure.
Check all MSA fans and
ensure they are operating.
Any failed fan should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the air
ow
and cooling ability of the
MSA.
408 STORAGE BOX
#<n> POWER SUPPLY
OK
Informational
The power supply in the
speci
ed storage enclosure
that was previously marked
as failed or degraded is
now operating normally.
409 STORAGE BOX
#<n> POWER SUPPLY
FAILED
Error
A power supply in the
speci
ed storage enclosure
has failed.
Check all power supplies and
ensure they are operating.
Any failed power supplies
should be replaced.
410 STORAGE BOX
#<n> POWER SUPPLY
ADDED
Informational
A power supply in the
speci
ed storage enclosure
has been added.
411 STORAGE BOX
#<n> POWER SUPPLY
REMOVED
Informational
A power supply in the
speci
ed storage enclosure
has been removed.
56