HP AD510A HP StorageWorks 1500 Modular Smart Array maintenance and service gui - Page 54

Recovery Rom, Autoflash Done, Autoflash Failed, Rom Cloning, Started, Failed, The Rom Auto

Page 54 highlights

Message 301 RECOVERY ROM AUTOFLASH DONE 302 RECOVERY ROM AUTOFLASH FAILED 303 ROM CLONING STARTED 304 ROM CLONING DONE 305 ROM CLONING FAILED Type Informational Error Informational Informational Error Description Action The array controller has successfully completed the process of copying the current active firmware image into the backup recovery ROM. The array controller failed to copy the current active firmware image into the backup recovery ROM. Recovery ROM support is disabled. Remove the failing array controller, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis. The ROM autoflash process is attempted again. Should the issue persist, contact HP support. In dual-controller MSA only, this indicates that the firmware from one of the controllers is being copied onto the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. If both array controllers are in the power-up sequence, then the most recent version of firmware will be used. If one array controller has already completed the power-up sequence and is active, then its version of firmware will be used even if less recent. In dual-controller MSA only, this indicates that the two array controllers in an MSA have finished copying one array controller's version of firmware to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. In dual-controller MSA only, this indicates that the two array controllers in an MSA failed to copy one array controller's version of firmware to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate. Remove the standby array controller, wait 10 seconds, and then reinsert the array controller ensuring that it is fully seated in the chassis. The ROM cloning process is attempted again. Should the issue persist, contact HP support. 54 LCD panel and message descriptions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Message
Type
Description
Action
301 RECOVERY ROM
AUTOFLASH DONE
Informational
The array controller has
successfully completed the
process of copying the
current active
rmware
image into the backup
recovery ROM.
302 RECOVERY ROM
AUTOFLASH FAILED
Error
The array controller failed
to copy the current active
rmware image into the
backup recovery ROM.
Recovery ROM support is
disabled.
Remove the failing array
controller, wait 10 seconds,
and then reinsert the array
controller, ensuring that it is
fully seated in the chassis.
The ROM auto
ash process
is attempted again.
Should the issue persist,
contact HP support.
303 ROM CLONING
STARTED
Informational
In dual-controller MSA
only, this indicates that
the
rmware from one of
the controllers is being
copied onto the other array
controller. Both controllers
must be running the same
version of
rmware in order
for controller redundancy to
operate.
If both array controllers are
in the power-up sequence,
then the most recent version
of
rmware will be used.
If one array controller has
already completed the
power-up sequence and is
active, then its version of
rmware will be used even
if less recent.
304 ROM CLONING
DONE
Informational
In dual-controller MSA only,
this indicates that the two
array controllers in an MSA
have
nished copying one
array controller's version of
rmware to the other array
controller. Both controllers
must be running the same
version of
rmware in order
for controller redundancy to
operate.
305 ROM CLONING
FAILED
Error
In dual-controller MSA
only, this indicates that the
two array controllers in an
MSA failed to copy one
array controller's version of
rmware to the other array
controller. Both controllers
must be running the same
version of
rmware in order
for controller redundancy to
operate.
Remove the
standby
array
controller, wait 10 seconds,
and then reinsert the array
controller ensuring that it is
fully seated in the chassis.
The ROM cloning process is
attempted again.
Should the issue persist,
contact HP support.
54
LCD panel and message descriptions