HP Pro Mini 260 G9 Desktop PC Maintenance and Service Guide - Page 83
POST numeric codes and text messages, continued, Table 7-1
View all HP Pro Mini 260 G9 Desktop PC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
Table 7-1 POST numeric codes and text messages (continued) Control panel message Description Recommended action 300-Configuration Change Warning A change in storage configuration has been detected (see Boot Options menu in BIOS Setup to enable this feature). Either the installed hardware has changed, storage or firmware mode might have been changed, or a storage device might have failed to respond. If no changes were made before this warning, check that the drives are connected properly to power cables and system board. User Diagnostics (f2 during boot-up) might help identify any problem with specific devices. 301-Hard Disk 1: SMART Hard Drive Detects Imminent Failure Hard drive will soon fail. (Some hard drives 1. Determine whether hard drive is have a hard drive firmware patch that will giving correct error message. Run the fix an erroneous error message.) Drive Protection System test under using F2 Diagnostics when booting the computer. 2. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) 3. Back up contents and replace hard drive. 302-Hard Disk 2: SMART Hard Drive Detects Imminent Failure Hard drive will soon fail. (Some hard drives 1. Determine whether hard drive is have a hard drive firmware patch that will giving correct error message. Run the fix an erroneous error message.) Drive Protection System test under using F2 Diagnostics when booting the computer. 2. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) 3. Back up contents and replace hard drive. 309 - 30C: Hard Disk 3-6: SMART Hard Drive Detects Imminent Failure Hard drive will soon fail. (Some hard drives 1. Determine whether hard drive is have a hard drive firmware patch that will giving correct error message. Run the fix an erroneous error message.) Drive Protection System test under using F2 Diagnostics when booting the computer. 2. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) 3. Back up contents and replace hard drive. 3F0-Boot Device Not Found Boot device not found. Insert boot device or load operating system. 3F1-Hard Disk 1 Error Hard disk 1 error. 1. Check and/or replace cables. 2. Clear CMOS. 3. Replace the hard disk drive. 3F2-Hard Disk 2 Error Hard disk 2 error. 1. Check and/or replace cables. 2. Clear CMOS. 3. Replace the hard disk drive. 400-Serial Port A Address Conflict Detected Both external and internal serial ports are 1. Remove any serial port expansion assigned to the same resources. cards. 2. Clear CMOS. 76 Chapter 7 POST error messages