HP ProLiant 1500 SMART-2DH Array Controller Reference Guide - Page 177

Slot x Drive Array - New Logical Drives, Slot x Drive Array - Array Accelerator Memory

Page 177 highlights

H-2 POST Error Messages continued POST Error Messages continued 1726 Slot x Drive Array - Array Accelerator Memory Size Change Detected. This message indicates that the array accelerator configuration has been updated automatically due to replacement of the Array Accelerator (or controller) with one having different memory size. Select F1 key to resume. 1727 Slot x Drive Array - New Logical Drive(s) Attachment Detected. If more than 32 logical drives, this message will be followed by: Auto-configuration failed: Too many logical drives. This message indicates that the controller has detected an additional array of drives that was attached when the power was off. The logical drive configuration information has been updated to add the new logical drives. The maximum number of logical drives supported is 32-additional logical drives will not be added to the configuration. Select F1 key to resume. 1764 Slot x Drive Array - Capacity Expansion Process is Temporarily Disabled (followed by one of the following:) 1. Expansion will resume when Array Accelerator has been reattached. 2. Expansion will resume when Array Accelerator has been replaced. 3. Expansion will resume when Array Accelerator RAM allocation is successful. 4. Expansion will resume when Array Accelerator battery reaches full charge. 5. Expansion will resume when Automatic Data Recovery has been Completed. (RESUME = F1 KEY) The capacity expansion process has been temporarily disabled for the reason indicated, and will automatically resume. If the array accelerator has been removed, you must reinstall it for capacity expansion to continue. 1765 Slot x Drive Array Option ROM Appears to Conflict with an ISA Card - ISA cards with 16-bit memory cannot be configured in Remove or reconfigure the conflicting ISA card, referring to the directions provided with the ISA card. Alternatively, the Option ROM can be Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: O-APPH.DOC Last Saved On: 2/27/98 12:10 PM COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

H-2
POST Error Messages
Writer: Pamela King
Project: SMART-2DH Array Controller Reference Guide
Comments: 295469-002
File Name: O-APPH.DOC
Last Saved On: 2/27/98 12:10 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
continued
POST Error Messages
continued
1726
Slot x Drive Array - Array Accelerator Memory
Size Change Detected.
This message indicates that the array
accelerator configuration has been updated
automatically due to replacement of the Array
Accelerator (or controller) with one having
different memory size. Select
F1
key to
resume.
1727
Slot x Drive Array - New Logical Drive(s)
Attachment Detected. If more than 32 logical
drives, this message will be followed by:
Auto-configuration failed: Too many logical
drives.
This message indicates that the controller has
detected an additional array of drives that was
attached when the power was off. The logical
drive configuration information has been
updated to add the new logical drives. The
maximum number of logical drives supported
is 32-additional logical drives will not be added
to the configuration. Select
F1
key to resume.
1764
Slot x Drive Array - Capacity Expansion
Process is Temporarily Disabled (followed by
one of the following:)
1. Expansion will resume when Array
Accelerator has been reattached.
2. Expansion will resume when Array
Accelerator has been replaced.
3. Expansion will resume when Array
Accelerator RAM allocation is successful.
4. Expansion will resume when Array
Accelerator battery reaches full charge.
5. Expansion will resume when Automatic
Data Recovery has been Completed.
(RESUME =
F1
KEY)
The capacity expansion process has been
temporarily disabled for the reason indicated,
and will automatically resume. If the array
accelerator has been removed, you must
reinstall it for capacity expansion to continue.
1765
Slot x Drive Array Option ROM Appears to
Conflict with an ISA Card - ISA cards with
16-bit memory cannot be configured in
Remove or reconfigure the conflicting ISA card,
referring to the directions provided with the ISA
card. Alternatively, the Option ROM can be