HP ProLiant 1500 SMART-2DH Array Controller Reference Guide - Page 29

Updating the Firmware, ROMPaq Diskettes

Page 29 highlights

3-1 Chapter 3 Updating the Firmware The ROMs on all Compaq servers and most Compaq options can be updated easily. This is done by flashing the ROM using a special Compaq utility called ROMPaq, which replaces the existing contents of the ROM with another version stored in a disk file. This is a convenient way to distribute new firmware to keep Compaq products updated with the latest capabilities. There are two ROMPaq utilities: System ROMPaq for updating the system ROM in all Compaq servers supporting Flash ROM. Use System ROMPaq when installing a new SMART-2DH Controller in a Compaq server to be sure that the server can utilize all the capabilities of the SMART-2DH Array Controller. Option ROMPaq for updating the onboard ROM on all Compaq options that support flashing. Use Option ROMPaq when new versions of the SMART-2DH Array Controller firmware or SCSI drive firmware become available to take advantage of expanded capabilities. IMPORTANT: Before you install the new SMART-2DH Array Controller in your server, you must run System ROMPaq to update the system firmware. Use the instructions below to create diskettes with the latest version of System ROMPaq from the Compaq SmartStart and Support Software CD supplied with the SMART-2DH Controller. ROMPaq Diskettes The ROMPaq utilities must be run from diskette(s). The latest version of the ROMPaq diskettes may be created from the Compaq SmartStart and Support Software CD that was supplied in the SMART-2DH Controller Option Kit. We recommend that you initially use this version of ROMPaq because it is the latest one that supports your new SMART-2DH Controller. SMART-2DH Array Controller Reference Guide Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: D-CH03.DOC Last Saved On: 2/27/98 11:26 AM COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

3-1
SMART-2DH Array Controller Reference Guide
Writer: Pamela King
Project: SMART-2DH Array Controller Reference Guide
Comments: 295469-002
File Name: D-CH03.DOC
Last Saved On: 2/27/98 11:26 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Chapter 3
Updating the Firmware
The ROMs on all Compaq servers and most Compaq options can be updated
easily. This is done by
flashing
the ROM using a special Compaq utility called
ROMPaq, which replaces the existing contents of the ROM with another
version stored in a disk file. This is a convenient way to distribute new
firmware to keep Compaq products updated with the latest capabilities.
There are two ROMPaq utilities:
System ROMPaq
for updating the system ROM in all Compaq servers
supporting Flash ROM. Use System ROMPaq when
installing a new SMART-2DH Controller in a Compaq
server to be sure that the server can utilize all the
capabilities of the SMART-2DH Array Controller.
Option ROMPaq
for updating the onboard ROM on all Compaq options that
support flashing. Use Option ROMPaq when new versions
of the SMART-2DH Array Controller firmware or SCSI
drive firmware become available to take advantage of
expanded capabilities.
IMPORTANT:
Before you install the new SMART-2DH Array Controller in
your server, you must run System ROMPaq to update the system firmware.
Use the instructions below to create diskettes with the latest version of
System ROMPaq from the Compaq SmartStart and Support Software CD
supplied with the SMART-2DH Controller.
ROMPaq Diskettes
The ROMPaq utilities must be run from diskette(s). The latest version of the
ROMPaq diskettes may be created from the Compaq SmartStart and Support
Software CD that was supplied in the SMART-2DH Controller Option Kit.
We recommend that you initially use this version of ROMPaq because it is the
latest one that supports your new SMART-2DH Controller.