HP Spectre Folio 13-ak1000 Maintenance and Service Guide - Page 63
from the lower frame. The transfer board ribbon cable is, Remove the transfer board cable
View all HP Spectre Folio 13-ak1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
1. Release the transfer board ribbon cable (1) from beneath the retention band. 2. Release the transfer board cable (2) from the retention clips (3) built into the lower frame. 3. Detach the transfer board ribbon cable (4) from the lower frame. (The transfer board ribbon cable is attached to the lower frame with adhesive.) 4. Remove the transfer board cable (5). Reverse this procedure to install the transfer board cable. Component replacement procedures 55
1.
Release the transfer board ribbon cable
(1)
from beneath the retention band.
2.
Release the transfer board cable
(2)
from the retention clips
(3)
built into the lower frame.
3.
Detach the transfer board ribbon cable
(4)
from the lower frame. (The transfer board ribbon cable is
attached to the lower frame with adhesive.)
4.
Remove the transfer board cable
(5)
.
Reverse this procedure to install the transfer board cable.
Component replacement procedures