SMART Execute Off-line Immediate [B0h, Sub D4h]

Page 62 highlights

6.3.2.8.11 SMART Execute Off-line Immediate [B0h, Sub D4h] Task File Registers Command Cylinder High Cylinder Low Device/Head Sector Number Sector Count Features DRV : Device selection bit 76543210 B0h C2h 4Fh - X - DRV XX XX XX D4h 0 : DRV0 1:DRV1 This command causes the device to immediately initiate the optional set of off-line data collection activities that collect attribute data in an off-line mode and then save this data to the device, or execute a selfdiagnostic test routine in either captive or off-line mode. Table 6.11 SMART EXECUTE OFF-LINE IMMEDIATE Sector Number register values Value Description of subcommand to be executed 0 Execute SMART off-line routine immediately in off-line mode 1 Execute SMART Short self-test routine immediately in off-line mode 2 Execute SMART Extended self-test routine immediately in off-line mode 3 - 63 Reserved 64 - 125 Reserved (Vendor specific) 126 Abort off-line mode off-line routine (Vendor specific) 127 Abort off-line mode self-test routine 128 Reserved 129 Execute SMART Short self-test routine immediately in captive mode 130 Execute SMART Extended self-test routine immediately in captive mode 131- 191 Reserved 192 - 255 Reserved (Vendor Specific) K6602637 Rev.3 02.27.01 - 62 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

K6602637
Rev.3
02.27.01
- 62 -
6.3.2.8.11 SMART Execute Off-line Immediate [B0h, Sub D4h]
Task File Registers
7
6
5
4
3
2
1
0
Command
B0h
Cylinder High
C2h
Cylinder Low
4Fh
Device/Head
-
X
-
DRV
XX
Sector Number
XX
Sector Count
XX
Features
D4h
DRV : Device selection bit
0 : DRV0
1:DRV1
This command causes the device to immediately initiate the optional set of off-line data collection activities
that collect attribute data in an off-line mode and then save this data to the device, or execute a self-
diagnostic
test routine in either captive or off-line mode.
Table 6.11
SMART EXECUTE OFF-LINE IMMEDIATE Sector Number register values
Value
Description of subcommand to be executed
0
Execute SMART off-line routine immediately in off-line mode
1
Execute SMART Short self-test routine immediately in off-line mode
2
Execute SMART Extended self-test routine immediately in off-line mode
3 - 63
Reserved
64 - 125
Reserved (Vendor specific)
126
Abort off-line mode off-line routine (Vendor specific)
127
Abort off-line mode self-test routine
128
Reserved
129
Execute SMART Short self-test routine immediately in captive mode
130
Execute SMART Extended self-test routine immediately in captive mode
131- 191
Reserved
192 - 255
Reserved (Vendor Specific)