IBM 8487 User Manual - Page 95

System board LEDs, For a = 0

Page 95 highlights

Note: See Chapter 8, "Parts listing, Type 8482 and 8487," on page 99 to determine which components are replaceable by the customer (CRU), and which components must be replaced by a field service technician (FRU). Error code/symptom FRU/action 217-198-XXX (Could not establish drive parameters) 1. Check cable and termination. 2. Hard disk drive backplane. 3. SCSI daughter card 4. Hard disk drive. 217-XXX-00n (Failed hard disk drive test) Note: If RAID is configured, the hard disk drive number refers to the RAID logical array. 1. Hard disk drive n 2. SCSI card 3. Hard disk drive backplane 301-XXX-000 (Failed keyboard test) v Keyboard v System board 302-XXX-000 (Failed mouse test) v Mouse v System board 405-XXX-000 (Failed Ethernet test on controller on the system board) 1. Verify that Ethernet is not disabled in BIOS. 2. System board. 405-XXX-00n (Failed Ethernet test on adapter in PCI slot n) 1. For n=0, system board 2. For n>0, adapter in PCI slot n 3. System board 405-XXX-a0n 1. For a = 0, system board (Failed Ethernet test on adapter in PCI slot a) 2. For a > 0, adapter in PCI slot a 415-XXX-000 (Failed Modem test) Note: Error message may indicate modem is not supported. 1. Cable Note: Ensure modem is present and attached to server. 2. Modem 3. System board System board LEDs Note: See Chapter 8, "Parts listing, Type 8482 and 8487," on page 99 to determine which components are replaceable by the customer (CRU), and which components must be replaced by a field service technician (FRU). LED FRU/action DIMM x 1. DIMM x 2. System board Standby power 1. Power supply Note: Normal operation is indicated when this LED is lit and 2. System board the server is connected to an ac power source. A problem is indicated if the LED is not lit when connected to ac power. System fan 2 1. Fan 2 2. System board Chapter 7. Symptom-to-FRU index 85

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

Note:
See Chapter 8, “Parts listing, Type 8482 and 8487,” on page 99 to determine which components are
replaceable by the customer (CRU), and which components must be replaced by a field service technician (FRU).
Error code/symptom
FRU/action
217-198-XXX
(Could not establish drive parameters)
1.
Check cable and termination.
2.
Hard disk drive backplane.
3.
SCSI daughter card
4.
Hard disk drive.
217-XXX-00n
(Failed hard disk drive test)
Note:
If RAID is configured, the hard disk
drive number refers to the RAID logical
array.
1.
Hard disk drive n
2.
SCSI card
3.
Hard disk drive backplane
301-XXX-000
(Failed keyboard test)
v
Keyboard
v
System board
302-XXX-000
(Failed mouse test)
v
Mouse
v
System board
405-XXX-000
(Failed Ethernet test on controller on the
system board)
1.
Verify that Ethernet is not disabled in BIOS.
2.
System board.
405-XXX-00n
(Failed Ethernet test on adapter in PCI slot
n)
1.
For n=0, system board
2.
For n>0, adapter in PCI slot n
3.
System board
405-XXX-a0n
(Failed Ethernet test on adapter in PCI slot
a)
1.
For a = 0, system board
2.
For a > 0, adapter in PCI slot a
415-XXX-000
(Failed Modem test)
Note:
Error message may indicate modem
is not supported.
1.
Cable
Note:
Ensure modem is present and attached to server.
2.
Modem
3.
System board
System board LEDs
Note:
See Chapter 8, “Parts listing, Type 8482 and 8487,” on page 99 to determine which components are
replaceable by the customer (CRU), and which components must be replaced by a field service technician (FRU).
LED
FRU/action
DIMM x
1.
DIMM x
2.
System board
Standby power
Note:
Normal operation is
indicated when this LED is lit and
the server is connected to an ac
power source. A problem is
indicated if the LED is not lit
when connected to ac power.
1.
Power supply
2.
System board
System fan 2
1.
Fan 2
2.
System board
Chapter 7. Symptom-to-FRU index
85