IBM 8649 Hardware Maintenance Manual - Page 118
Error, Symptom, FRU/Action, during, Fixed, diagnostic, drives, recognized, fixed, diagnostic.,
UPC - 000435133427
View all IBM 8649 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Error Symptom Hang during Fixed Disk diagnostic Not all drives are recognized by fixed disk diagnostic. System hangs during fixed disk diagnostic. FRU/Action Remove the hard disk drive being tested at the time of the hang. Rerun the diagnostic. If successful, replace the drive you removed. 1. Remove first drive that does not show up and rerun diagnostic. If remaining drives show up, replace the one that was removed. 2. If remaining drives do not show up, remove successive drives one at a time and rerun diagnostic. Remove hard drive being tested at the time of the hang and rerun the diagnostic. If successful, replace drive that was removed. Note: See "System replaceable units" on page 122 to determine which components should be replaced by a field service technician. Symptom to FRU list Symptom FRU/action Microprocessor test failed. Microprocessor System timer test failed. System board Memory test failed. v DIMM v System board RAM refresh test failed. System board ECC controller logic. System board CMOS RAM test failed. System board Keyboard controller test failed. System board External cache test failed. Microprocessor PCI test failed. System board USB interface test failed. System board USB port test failed. System board Video test failed. Mini-PCI video adapter Serial port test failed. System board Parallel port test failed. System board SCSI controller test failed. System board Hard disk drive test failed. 1. Hard disk drive 2. Hard disk drive cable Diskette drive test failed. 1. Diskette drive 2. Diskette drive cable 3. System board Integrated SP test failed. System board System management test failed. 1. Remote Supervisor adapter, if installed. 2. System board. CD-ROM test failed. 1. CD-ROM drive 2. CD-ROM drive cable 3. System board Ethernet test failed. System board ServeRAID test failed. RAID controller 108 IBM xSeries 225 Types 8649: Hardware Maintenance Manual and Troubleshooting Guide