IBM 867282X Maintenance Manual - Page 68

Dual input instructions, Disconnecting the DC Power Connection

Page 68 highlights

Dual input instructions Complete the following steps to connect dual - 48 V dc power inputs to the power supply terminals. Note: For instructions on how to connect a single input to the terminal block, refer to "Single input instructions" on page 58. 1. Pull down on the terminal cover to open it. 2. Connect the protective ground wire to the protective ground terminal located in the center of the terminal block. Note: The wires must be connected in the order described to ensure the proper operation of the - 48 V. Protective ground terminal Return terminal 0 V (+) Terminal block cover -48 V terminals (--) 3. Connect the first set of inputs to the A set of terminals as follows: a. Connect the return or 0 V wire to the A return (+) terminal on the terminal block. b. Connect the - 48 V (-) wire to the A (-) terminal on the terminal block. 4. Connect the first set of inputs to the B set of terminals as follows: a. Connect the return or 0 V wire to the B return (+) terminal on the terminal block. b. Connect the - 48 V (-) wire to the B (-) terminal on the terminal block. Note: Torque the wiring-terminal screws to 12 inch-pounds (1.4 newton-meters). 5. Close the terminal block cover. Disconnecting the DC Power Connection The information in this section replaces the instructions for turning off the server and disconnecting the power cable from the rear of the server in your xSeries documentation. Statement 19 CAUTION: 60 Hardware Maintenance Manual: xSeries 300

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Dual input instructions
Complete the following steps to connect dual
48 V dc power inputs to the power
supply terminals.
Note:
For instructions on how to connect a single input to the terminal block, refer
to
Single input instructions
on page 58.
1.
Pull down on the terminal cover to open it.
2.
Connect the protective ground wire to the protective ground terminal located in
the center of the terminal block.
Note:
The wires must be connected in the order described to ensure the proper
operation of the
48 V.
Protective
ground terminal
Return terminal
0 V
(
)
+
Terminal block
cover
-48 V terminals (
)
--
3.
Connect the first set of inputs to the A set of terminals as follows:
a.
Connect the return or 0 V wire to the A return (+) terminal on the terminal
block.
b.
Connect the
48 V (
) wire to the A (
) terminal on the terminal block.
4.
Connect the first set of inputs to the B set of terminals as follows:
a.
Connect the return or 0 V wire to the B return (+) terminal on the terminal
block.
b.
Connect the
48 V (
) wire to the B (
) terminal on the terminal block.
Note:
Torque the wiring-terminal screws to 12 inch-pounds (1.4
newton-meters).
5.
Close the terminal block cover.
Disconnecting the DC Power Connection
The information in this section replaces the instructions for turning off the server
and disconnecting the power cable from the rear of the server in your xSeries
documentation.
Statement 19
CAUTION:
60
Hardware Maintenance Manual: xSeries 300