Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S., DIMM Location J1-J4
UPC - 087944650966
View all IBM 867282X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
Error Code/Symptom FRU/Action 035-XXX-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) 1. Adapter 2. SCSI Backplane 3. Cable 035-XXX-SNN 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. (Check System Error Log before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. Adapter 075-XXX-000 1. Power Supply (Failed Power Supply test) 089-XXX-001 1. Microprocessor (Failed Microprocessor test) 180-XXX-003 1. System Board (Failed System Board LED test) 201-XXX-0NN (Failed Memory test) NN = DIMM location. 1. DIMM Location J1-J4 2. Memory card 201-XXX-999 1. See error text for failing DIMMs (Multiple DIMM failure, see error text.) 202-XXX-001 1. Microprocessor CPU 1 (Failed System Cache test) 206-XXX-000 (Failed Diskette Drive test) 1. Cable 2. Diskette Drive 3. System Board 215-XXX-000 (Failed IDE CD-ROM test) 1. CD-ROM Drive Cables 2. CD-ROM Drive 3. System Board 217-XXX-000 1. Fixed Disk 1 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. Chapter 7. Symptom-to-FRU index 65