IBM 867282X Maintenance Manual - Page 73

Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S., DIMM Location J1-J4

Page 73 highlights

Error Code/Symptom FRU/Action 035-XXX-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) 1. Adapter 2. SCSI Backplane 3. Cable 035-XXX-SNN 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. (Check System Error Log before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. Adapter 075-XXX-000 1. Power Supply (Failed Power Supply test) 089-XXX-001 1. Microprocessor (Failed Microprocessor test) 180-XXX-003 1. System Board (Failed System Board LED test) 201-XXX-0NN (Failed Memory test) NN = DIMM location. 1. DIMM Location J1-J4 2. Memory card 201-XXX-999 1. See error text for failing DIMMs (Multiple DIMM failure, see error text.) 202-XXX-001 1. Microprocessor CPU 1 (Failed System Cache test) 206-XXX-000 (Failed Diskette Drive test) 1. Cable 2. Diskette Drive 3. System Board 215-XXX-000 (Failed IDE CD-ROM test) 1. CD-ROM Drive Cables 2. CD-ROM Drive 3. System Board 217-XXX-000 1. Fixed Disk 1 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. Chapter 7. Symptom-to-FRU index 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Error Code/Symptom
FRU/Action
035-XXX-S99
(Failed RAID test on PCI slot
S. S = number of failing PCI
slot. Check System Error Log
before replacing a FRU.)
1.
Adapter
2.
SCSI Backplane
3.
Cable
035-XXX-SNN
(Check System Error Log
before replacing a FRU. S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)
1.
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99
(RAID adapter initialization
failure)
1.
ServeRAID Adapter in slot S is not configured properly.
Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2.
Cable
3.
Adapter
075-XXX-000
(Failed Power Supply test)
1.
Power Supply
089-XXX-001
(Failed Microprocessor test)
1.
Microprocessor
180-XXX-003
(Failed System Board LED
test)
1.
System Board
201-XXX-0NN
(Failed Memory test) NN =
DIMM location.
1.
DIMM Location J1-J4
2.
Memory card
201-XXX-999
(Multiple DIMM failure, see
error text.)
1.
See error text for failing DIMMs
202-XXX-001
(Failed System Cache test)
1.
Microprocessor CPU 1
206-XXX-000
(Failed Diskette Drive test)
1.
Cable
2.
Diskette Drive
3.
System Board
215-XXX-000
(Failed IDE CD-ROM test)
1.
CD-ROM Drive Cables
2.
CD-ROM Drive
3.
System Board
217-XXX-000
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured,
the fixed disk number refers
to the RAID logical array.
1.
Fixed Disk 1
Chapter 7. Symptom-to-FRU index
65