Intel QX9770 Design Guidelines - Page 78

Supporting Test Equipment, Description, Part Number, Measurement and Output

Page 78 highlights

Case Temperature Reference Metrology D.2 Supporting Test Equipment To apply the reference thermocouple attach procedure, it is recommended to use the equipment (or equivalent) given in the table below. Item Description Part Number Measurement and Output Microscope DMM Thermal Meter Olympus* Light microscope or equivalent SZ-40 Digital Multi Meter for resistance measurement Fluke 79 Series Hand held thermocouple meter Multiple Vendors Solder Station (see note 1 for ordering information) Heater Block Heater Transformer Heater assembly to reflow solder on IHS WATLOW120V 150W Firerod Superior Powerstat transformer Miscellaneous Hardware 30330 0212G G1A38L12 05F857 Solder Flux Loctite* 498 Adhesive Adhesive Accelerator Kapton* Tape Thermocouple Indium Corp. of America Alloy 57BI / 42SN / 1AG 0.010 Diameter Indium Corp. of America Super glue w/thermal characteristics Loctite* 7452 for fast glue curing For holding thermocouple in place Omega *,36 gauge, "T" Type (see note 2 for ordering information) Calibration and Control 52124 5RMA 49850 18490 Not Available OSK2K1280/5SR TC-TT-T-36-72 Ice Point Cell Hot Point Cell Omega*, stable 0 ºC temperature source for calibration and offset Omega *, temperature source to control and understand meter slope gain TRCIII CL950-A-110 NOTES: 1. The Solder Station consisting of the Heater Block, Heater, Press and Transformer are available from Jemelco Engineering 480-804-9514 2. This part number is a custom part with the specified insulation trimming and packaging requirements necessary for quality thermocouple attachment, See Figure 31. Order from Omega Anthony Alvarez, Direct phone (203) 359-7671, Direct fax (203) 9687142, E-Mail: [email protected] 78 Thermal and Mechanical Design Guidelines

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

Case Temperature Reference Metrology
78
Thermal and Mechanical Design Guidelines
D.2
Supporting Test Equipment
To apply the reference thermocouple attach procedure, it is recommended to use the
equipment (or equivalent) given in the table below.
Item
Description
Part Number
Measurement and Output
Microscope
Olympus* Light microscope or equivalent
SZ-40
DMM
Digital Multi Meter for resistance measurement
Fluke 79 Series
Thermal Meter
Hand held thermocouple meter
Multiple Vendors
Solder Station (see note 1 for ordering information)
Heater Block
Heater assembly to reflow solder on IHS
30330
Heater
WATLOW120V 150W Firerod
0212G G1A38-
L12
Transformer
Superior Powerstat transformer
05F857
Miscellaneous Hardware
Solder
Indium Corp. of America
Alloy 57BI / 42SN / 1AG
0.010 Diameter
52124
Flux
Indium Corp. of America
5RMA
Loctite* 498
Adhesive
Super glue w/thermal characteristics
49850
Adhesive
Accelerator
Loctite* 7452 for fast glue curing
18490
Kapton* Tape
For holding thermocouple in place
Not Available
Thermocouple
Omega *,36 gauge,
“T” Type
(see note 2 for ordering information)
OSK2K1280/5SR
TC-TT-T-36-72
Calibration and Control
Ice Point Cell
Omega*, stable 0 ºC temperature source for
calibration and offset
TRCIII
Hot Point Cell
Omega *, temperature source to control and
understand meter slope gain
CL950-A-110
NOTES:
1.
The Solder Station consisting of the Heater Block, Heater, Press and Transformer are
available from Jemelco Engineering 480-804-9514
2.
This part number is a custom part with the specified insulation trimming and packaging
requirements necessary for quality thermocouple attachment, See Figure 31.
Order
from Omega Anthony Alvarez, Direct phone (203) 359-7671, Direct fax
(203) 968-
7142, E-Mail: [email protected]