Intel SC5600BASE Service Guide

Intel SC5600BASE Manual

Intel SC5600BASE manual content summary:

  • Intel SC5600BASE | Service Guide - Page 1
    Intel® Server Chassis SC5600 Service Guide A Guide for Technically Qualified Assemblers of Intel® identified Subassemblies/Products Order Number: E39533-003 Revision 1.1
  • Intel SC5600BASE | Service Guide - Page 2
    Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2010, Intel Corporation. All Rights Reserved ii Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 3
    este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel® Server Deployment Toolkit 3.0 CD y/o en: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm Intel® Server Chassis SC5600 Service Guide iii
  • Intel SC5600BASE | Service Guide - Page 4
    the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. iv Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 5
    you may need, troubleshooting information, and instructions on how to add and replace components on the Intel® Server Chassis SC5600. For the latest version of this manual, refer to: http://support.intel.com/support/motherboards/server/chassis/SC5600/ Manual Organization Chapter 1 provides
  • Intel SC5600BASE | Service Guide - Page 6
    server/workstation board standoff spares In addition, you may need or want to purchase one or more of the following accessory items for your server: „ Processor „ Memory DIMMs „ Hard drive „ CD-ROM or DVD-ROM drive „ RAID controller „ Operating system vi Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 7
    Preface For information about compatible accessories, memory, processors, and third-party hardware and ordering information for Intel products, see: http://support.intel.com/support/motherboards/server/chassis/SC5600/compat.htm Additional Information and Software If you need more information about
  • Intel SC5600BASE | Service Guide - Page 8
    Preface viii Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 9
    1 Server Chassis Features 1 Component Identification ...5 Front Control Panel...7 Intel® Local Control Panel ...8 Back Panel Features ...9 Peripheral Devices...11 Standard and Optional Hot-swap Drive Bays 12 Intel® Remote Management Module 3 12 Rack-mount Systems...12 Tower Passive Processor Heat
  • Intel SC5600BASE | Service Guide - Page 10
    57 System Environmental Specification 58 Current Usage Statement (USA 64 Industry Canada (ICES-003 64 Europe Server 71 Sicherheitshinweise und Vorsichtsmaßnahmen 71 Zielbenutzer der Anwendung 72 Standortauswahl ...72 Handhabung von Geräten 72 x Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 11
    Server Issue Report Form 98 Appendix F: Warranty 103 Limited Warranty for Intel® Chassis Subassembly Products 103 Extent of Limited Warranty 103 Warranty Limitations and Exclusions 103 Limitations of Liability 104 How to Obtain Warranty Service 104 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 12
    Swap Cage 41 Figure 46. Removing Plastic Air Baffle from Drive Carrier 41 Figure 47. Securing Hard Drive to Drive Carrier 42 Figure 48. Inserting Drive Carrier into Hot Swap Cage 42 Figure 49. Preparing Chassis for Removal of PCI add-in board 43 xii Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 13
    Output Capability 57 Table 6. 750-W Hot Swap Power Supply Output Capability 58 Table 7. Environmental Specification 58 Table 8. Power Usage Worksheet 59 Table 9. Power Usage Worksheet 2 60 Table 10. Product Regulatory Compliance Markings 63 Intel® Server Chassis SC5600 Service Guide xiii
  • Intel SC5600BASE | Service Guide - Page 14
  • Intel SC5600BASE | Service Guide - Page 15
    six drives, depending on peripheral choices ƒ One fixed drive bay for up to six fixed SAS or SATA drives ƒ Optional hot-swap drive bays: • Six-drive SAS/SATA (AXX6DRV3GR or AXX6DRV3GEXP) ƒ Three multi-mount 5.25-inch peripheral bays ƒ Front Control Panel Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 16
    (AXX6DRV3GR or AXX6DRV3GEXP) • 4-drive SAS/SATA (AXX4DRV3GR or AXX4DRV3GEXP) ƒ Three multi-mount 5.25 peripheral bays ƒ Front Control Panel ƒ Intel® Local Control Panel (Optional) ƒ With Front Control Panel • NIC1 Activity • NIC2 Activity • Power/Sleep 2 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 17
    Panel ƒ Intel® Local Control Panel (Optional) ƒ With Front Control Panel • NIC1 Activity • NIC2 Activity • Power/Sleep • System Status • System Identification • Hard Drive Activity ƒ (1+1) hot-swap redundant PFC high-efficiency 750-W PMBus-compliant Intel® Server Chassis SC5600 Service Guide 3
  • Intel SC5600BASE | Service Guide - Page 18
    ) is required when used with compatible Intel® server/workstation board ƒ Supports up to 95-W processor ƒ Two front panel USB ports with Front Control Panel ƒ Four back panel USB ports (depending on server/workstation board) ƒ One rear panel video port 4 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 19
    USB/Serial B 4. Air Duct and Rear Fixed Fan 10. Fixed Drive Cage 4-Drive (accessory) 5. Front Fixed Fans (2) 11. Fixed Drive Cage 6-Drive 6. Hard Disk Drive Cage Release Mechanisms (2) Figure 2. Intel® Server Chassis SC5600Base Components Location Intel® Server Chassis SC5600 Service Guide 5
  • Intel SC5600BASE | Service Guide - Page 20
    11. Front Panel USB/Serial B 5. Air Duct 12. Hot-swap Drive Cage 4-Drive (accessory) 6. Hot-swap Fans - Large (2) 13. Hot-swap Drive Cage 6-Drive (accessory) 7. Hot-swap Fans -Small (2) Figure 3. Intel® Server Chassis SC5600LX Components Location 6 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 21
    Chassis Features A. ID LED Toggle Switch B. Reset Button C. NIC1 Activity LED (green) D. Power Button E. Hard Drive Activity LED (green) F. NIC2 Activity LED (green) G. ID LED (blue) H. Status LED (bi-color) I. NMI Button Figure 4. Front Control Panel Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 22
    Intel® Local Control Panel provides enhanced system control by using a LCD display, which provides additional controls and indicators beyond the standard control panel. The following figure shows the features available on the Intel® Local Control Panel. 8 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 23
    Callout Function A LCD display (variable content) B LCD up navigation button C LCD down navigation button D LCD backup level navigation button E LCD command enter button Figure 5. Intel® Local Control Panel Features Back Panel Features Intel® Server Chassis SC5600 Service Guide 9
  • Intel SC5600BASE | Service Guide - Page 24
    -in Card Slots PCI Card Latch Rear Serial B Connector (optional) AC Power Connector / NOTE I/O ports vary, depending on the server/workstation board installed. See your server board documentation for port identification. Figure 6. Server Chassis Back 10 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 25
    figure shows the available options. Callout A. B. C. D. Function DVD-ROM drive/CD-ROM drive (Optional) Front USB ports (2) 4-Bay hot-swap hard disk drive bay (optional) 6-Bay hot-swap hard disk drive bay (optional) Figure 7. Optional Peripherals Intel® Server Chassis SC5600 Service Guide 11
  • Intel SC5600BASE | Service Guide - Page 26
    for an Internal link to a list of supported hardware. See "Drive Cage Upgrade Kit Installation Guide: Intel® Server Chassis SC5400 and SC5600" for installing hotswap hard drive bays. Intel® Remote Management Module 3 The Intel® Remote Management Module 3 (Intel® RMM3) plugs into the connector on the
  • Intel SC5600BASE | Service Guide - Page 27
    Board S5520HC/S5500HCV into the Intel® Server Chassis SC5600LX. Two tower heat sinks are required for dualprocessor installation. This tower passive heat sink is NOT required for other Intel® Server Chassis in the Intel® Server Chassis SC5600 families. Intel® Server Chassis SC5600 Service Guide 13
  • Intel SC5600BASE | Service Guide - Page 28
    conductive foam pad (recommended) System Reference All references to the left, right, front, top, and bottom assume the reader is facing the front of the chassis as it would be positioned for normal operation. 14 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 29
    cover screw (see letter "A" in the following figure). While holding in the blue button at the top of the chassis (see letter "B"), slide the top cover back until it stops. Lift the cover outward to remove it. Figure 8. Removing the Chassis Cover Intel® Server Chassis SC5600 Service Guide 15
  • Intel SC5600BASE | Service Guide - Page 30
    assembly consists of two components: a front door and a sub-bezel. 1. Observe the safety and ESD precautions at the beginning of this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 16 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 31
    Configuration Only) CAUTION This step applies to a pedestal configuration chassis only. For instructions on installing a bezel in a rack-mount configuration, refer to the Rack Conversion Kit Installation Guide: Intel® Server Chassis SC5400 and SC5600. 1. Open the outer bezel door of the bezel
  • Intel SC5600BASE | Service Guide - Page 32
    at the beginning of this book. See "Appendix B: Safety Information". 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 26. 18 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 33
    the air duct and chassis rear fan bracket (see letter "D" in Figure 13) alignment rails (see letter "C" in Figure 13) before inserting air duct tabs (see letter "B" in Figure 13) into the chassis rear fan bracket slots (see letter "A" in Figure 13). Intel® Server Chassis SC5600 Service Guide 19
  • Intel SC5600BASE | Service Guide - Page 34
    to align the air duct and chassis rear fan bracket alignment rails (see letter "E" in Figure 14) before inserting air duct tabs (see letters "B", "C", and "F" in Figure 14) into the matching chassis slots (see letters "A", "D", and "F" in Figure 14). 20 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 35
    the server board. 5. To replace the rear chassis fan, remove the air duct. For instructions, see "Removing the Air Duct." 6. Remove the 92-mm (see letter "A" in the following figure) or 120-mm (see letters "B" and "C") fixed fan from its snap-in bracket. Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 36
    Chassis SC5400BRP configurations ship with fixed fans. You cannot use the hot-swap fans from the Intel® Server Chassis SC5400LX or SC5400LXi in the Intel® Server Chassis SC5600LX. 1. Observe the safety and ESD precautions at the beginning of this book. 22 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 37
    the chassis cover if it was not removed in a previous step. For instructions, see "Removing the Chassis Cover." 3. Insert the hot swap fan into the chassis until it latches into place. 4. For insertion of the remaining hot swap fans, repeat Step 3. Intel® Server Chassis SC5600 Service Guide 23
  • Intel SC5600BASE | Service Guide - Page 38
    pressing in on the slide release latches (see letter "A" in Figure 18). Remove the slides from the DVD or CD-ROM drive by pulling the slides away from the drive (see letter "B"). A gentle pull should release the slide from the side dimple on the drive. 24 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 39
    from the upper device bay by pressing the two slide assembly latches inward (see letter "A" in Figure 20). Remove the slides from the EMI shield by pulling the slides away from the EMI shield to release them from the EMI shield (see letter "B"). Intel® Server Chassis SC5600 Service Guide 25
  • Intel SC5600BASE | Service Guide - Page 40
    . For instructions, see "Removing and Installing the Front Bezel." 10. Install the chassis cover. For instructions, see "Installing the Chassis Cover." 11. Plug all peripheral devices and the AC power cable into the server. 12. Power up the server. 26 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 41
    the drive cage from its drive bay slot in the chassis. Take care, however, to position the drive cage horizontally before opening the drive cage doors or the drive rails will spill out. Figure 22. Removing Six-drive Fixed Drive Cage from Chassis Intel® Server Chassis SC5600 Service Guide 27
  • Intel SC5600BASE | Service Guide - Page 42
    Open the upper door of the drive cage (see letter "B"). Figure 23. Unlocking and Opening Upper Door of Fixed Drive Cage 9. Open the lower door. Figure 24. Opening Lower Door of Fixed Drive Cage 10. Remove the drive/slide assembly from the drive cage. 28 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 43
    Drive Cage 11. Remove the device slides from the hard drive. If not replacing the hard drive, insert the empty device slides into the drive cage. Figure 26. Inserting Empty Device Slides into Fixed Drive Cage 12. Close the lower door of the drive cage. Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 44
    Hardware Installations and Upgrades Figure 27. Closing Lower Door of Fixed Drive Cage 13. Close the upper door. Figure 28. Closing Upper Door of Fixed Drive Cage 14. Tighten the captive screw. 30 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 45
    drive cage. / NOTE As an alternative, you may also fully remove the drive cage from its drive bay slot in the chassis. Take care, however, to position the drive cage horizontally before opening the drive cage doors or the drive rails will spill out. Intel® Server Chassis SC5600 Service Guide 31
  • Intel SC5600BASE | Service Guide - Page 46
    Figure 30. Removing Six-drive Fixed Drive Cage from Chassis 6. Loosen the captive screw (see letter "A" in Figure 31). Open the upper door (see letter "B"). Figure 31. Unlocking and Opening the Upper Door of Fixed Drive Cage 7. Open the lower door. 32 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 47
    less operation. Insert pins on device slides into mounting holes on the hard drive. Press firmly to secure device slides to the hard drive. Ensure the metal tabs on the device slides are facing the front of the hard drive and facing towards each other. Intel® Server Chassis SC5600 Service Guide 33
  • Intel SC5600BASE | Service Guide - Page 48
    hard drive faces towards the rear of the drive cage. Figure 35. Inserting Drive/Slide Assembly into Drive Cage 11. For installation of additional hard drives into the drive cage, repeat the previous steps. 12. Close the lower door of the drive cage. 34 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 49
    Hardware Installations and Upgrades Figure 36. Closing Lower Door of Fixed Drive Cage 13. Close the upper door. Figure 37. Closing Upper Door of Fixed Drive Cage 14. Tighten the captive screw. Intel® Server Chassis SC5600 Service Guide 35
  • Intel SC5600BASE | Service Guide - Page 50
    , see "Removing and Installing the Front Bezel." 18. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 27. 19. Plug all peripheral devices and the AC power cable into the server. 20. Power up the server. 36 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 51
    Hardware Installations and Upgrades Routing Power Cables to Fixed Drives Route the longest power cables to the 6-drive bay and shorter cables to the 4-drive bay and upper device bay. Figure 39. Routing Power Cables to Fixed Drives Intel® Server Chassis SC5600 Service Guide 37
  • Intel SC5600BASE | Service Guide - Page 52
    kit. ƒ Route SAS/SATA data cables through the chassis openings located near the bottom of the drive cage. ƒ Connect data cables to the respective fixed drive and to the appropriate connector on the server board. Figure 40. Routing SAS/SATA Data Cables 38 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 53
    the drive cage (see letter "C"). Figure 41. Removing Drive Carrier from Hot Swap Cage 2. Remove the four screws securing the hard drive to the drive carrier. Remove the hard drive from the drive carrier. Figure 42. Removing Hard Drive from Drive Carrier Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 54
    Air Baffle in Drive Carrier 4. With the black lever open, insert the drive carrier into the drive cage. Once inserted, rotate the black lever upwards to latch the drive carrier into position. Figure 44. Inserting Drive Carrier into Hot Swap Cage 40 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 55
    drive to the drive carrier using the four screws previously attached to the plastic air baffle. Ensure the connector end of the hard drive is facing the back of the drive carrier. The label side of the hard drive should be facing up in the drive carrier. Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 56
    Hard Drive to Drive Carrier 4. With the black lever open, insert the drive carrier into the drive cage. Once inserted, rotate the black lever upwards to latch the drive carrier into position. Figure 48. Inserting Drive Carrier into Hot Swap Cage 42 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 57
    in Figure 49) to release the PCI add-in card retainer from the chassis. Open the back panel PCI add-in card retention device (see letter "B") by pressing open from the inside of the chassis. Figure 49. Preparing Chassis for Removal of PCI add-in board Intel® Server Chassis SC5600 Service Guide 43
  • Intel SC5600BASE | Service Guide - Page 58
    Open the back panel PCI add-in card retention device (see letter "B") by pressing open from the inside of the chassis. Remove the PCI slot shield (see letter "C"), if it is not already removed, by pushing the shield out from the inside of the chassis. 44 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 59
    . 7. Hold the PCI add-in board by its top edge or upper corners. Firmly press the add-in board into an expansion slot on the server board (see letter "A" in the following figure). Close the back panel PCI add-in card retention device (see letter "B"). Intel® Server Chassis SC5600 Service Guide 45
  • Intel SC5600BASE | Service Guide - Page 60
    Hardware Installations and Upgrades Figure 51. Installing PCI Add-in Board 8. Repeat steps 2 through 10 until all PCI add-in cards are installed. 9. Reinstall the PCI Add-in Card Retainer. 46 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 61
    . For instructions, see "Removing and Installing the Front Bezel." 12. Install the chassis cover. For instructions, see "Installing the Chassis Cover." 13. Plug all peripheral devices and the AC power cable into the server. 14. Power up the server. Intel® Server Chassis SC5600 Service Guide 47
  • Intel SC5600BASE | Service Guide - Page 62
    into the chassis, and make sure the green latch (see letter "B" in Figure 54) secures the hot swap power supply to the power supply cage. Figure 54. Installing Hot Swap Power Supply into Chassis 4. Connect the power cable to the replaced power supply. 48 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 63
    the chassis air duct. For instructions, see "Installing the Air Duct." 12. Install the chassis cover. For instructions, see "Installing the Chassis Cover." 13. Plug all peripheral devices and the AC power cable into the server. 14. Power up the server. Intel® Server Chassis SC5600 Service Guide 49
  • Intel SC5600BASE | Service Guide - Page 64
    your Intel server/workstation board for the appropriate connection location. 7. Remove the screws (see letters "A" and "B" in the following figure) securing the filler panel to the chassis, and remove the power supply filler panel from the chassis. 50 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 65
    Hot Swap Power Supply Cage from Chassis 10. Remove the screws (see letter "A" and "B" in the following figure) securing the power distribution board to the hot swap supply cage, and detach the distribution board from the hot swap power supply cage. Intel® Server Chassis SC5600 Service Guide 51
  • Intel SC5600BASE | Service Guide - Page 66
    Figure 61. Attaching Power Distribution Board to Hot Swap Power Supply Cage 12. Re-insert the hot swap power supply cage into the chassis power supply bay. Try to route the power cables to the appropriate area at the time of insertion (see Step 13). 52 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 67
    board, and install the screws to secure the filler panel board to the chassis (see letters "A" and "B" in Figure 64). Figure 64. Installing Filler Panel board on the Chassis 15. Insert the hot swap power supplies into the chassis (see Figure 65). Intel® Server Chassis SC5600 Service Guide 53
  • Intel SC5600BASE | Service Guide - Page 68
    the chassis cover. For instructions, see "Removing the Chassis Cover." 4. If it is installed, remove the front bezel. For instructions, see chassis far enough so you can reach the front panel and USB cable connectors at the rear of the control panel. 54 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 69
    For instructions, see "Installing the Front Bezel (Pedestal Only)." 13. Re-install the chassis cover. For instructions, see "Installing the Chassis Cover." 14. Plug all peripheral devices and the AC power cable into the server. 15. Power up the server. Intel® Server Chassis SC5600 Service Guide 55
  • Intel SC5600BASE | Service Guide - Page 70
    1. If your server has a hot swap power supply, remove the cables (that route toward the server/workstation board) to the chassis. 2. See your Intel® Server/Workstation Board Service Guide or Quick Start User's Guide for cable connection locations. 56 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 71
    Technical Reference 3 Technical Reference Power Supply Specification 670-W Single Power Supply Input Voltage ƒ 100-127 V at 50/60 Hz; 12 A max. ƒ 200-240 about calculating the power usage for your configuration, see "Calculating Power Usage." Intel® Server Chassis SC5600 Service Guide 57
  • Intel SC5600BASE | Service Guide - Page 72
    humidity (non-condensing) at 30 °C. Operating: 2.0 g, 11 msec, 1/2 sine Packaged: Operational after an 18-inch free fall. Base, BRP, and LX configurations - 5.8 BA LWA idle; 6.0 BA LWA typical operating Tested to 15 kilovolts (kV); no component damage 58 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 73
    Drive Expansion Board 1 Expansion Board 2 Expansion Board 3 Expansion Board 4 Expansion Board 5 Expansion Board 6 Intel® Remote Management Module Table 8. Power Usage Worksheet Current (maximum) at voltage level +3.3 V +5 V -5 V +12 V -12 V 5 V Standby Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 74
    V -5 V +12 V -12 V 5 V Standby Worksheet, Total Combined Power Used by the Server ƒ From the previous worksheet, enter the total current for each column. ƒ Multiply the voltage by subsystem and may cause the power supplies to overheat and malfunction. 60 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 75
    adhere to the assembly instructions in this guide to ensure and maintain Compliance The server chassis complies with the following product safety requirements: • UL60950 - CSA 60950 (USA/Canada) • 73/23/EEE (Europe) • IRAM Certification (Argentina) Intel® Server Chassis SC5600 Service Guide 61
  • Intel SC5600BASE | Service Guide - Page 76
    system(s), refer to Intel's Server Builder Web site or contact your local Intel representative. • FCC /ICES-003 - Emissions (USA/Canada) Verification • CISPR Certification (Korea) • IRAM Certification (Argentina) • Ecology Declaration (International) 62 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 77
    cULus Listing Marks Region USA/Canada Marking GS Mark Germany CE Mark FCC Marking (Class A) Europe USA EMC Marking (Class A) VCCI Marking (Class A) Canada Japan BSMI Certification Number and Class A Warning GOST R Marking Taiwan Russia Intel® Server Chassis SC5600 Service Guide 63
  • Intel SC5600BASE | Service Guide - Page 78
    EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, and used in accordance with the instructions, may cause harmful interference to to radio and TV reception. Industry Canada (ICES-003) Cet appareil numérique Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 79
    to the instruction manual. BSMI (Taiwan intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. • Server Chassis: (base chassis is provided with power supply and fans) - UL listed. Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 80
    (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials for information on product recycling and/or take back. 66 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 81
    in serious injury or death if safety instructions are not followed. Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Server Chassis SC5600 Service Guide 67
  • Intel SC5600BASE | Service Guide - Page 82
    required. A separate AC cord is required for each system power supply. Some power supplies in Intel® servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that that is suitable for the electrical outlet. 68 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 83
    edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. Intel® Server Chassis SC5600 Service Guide 69
  • Intel SC5600BASE | Service Guide - Page 84
    problems. For proper cooling and airflow, operate the system only with the chassis . • Attach the covers to the chassis according to the product instructions. Laser Peripherals or Devices Caution: To serviceable. • Return to manufacturer for servicing. 70 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 85
    B: Safety Information Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie Gerät von der Netzspannung zu trennen. Bereiten Sie bitte Batterie auf. Intel® Server Chassis SC5600 Service Guide 71
  • Intel SC5600BASE | Service Guide - Page 86
    trennen Sie vor dem Öffnen des Geräts das Netzkabel sowie alle an den Server angeschlossene Telekommunikationssysteme, Netzwerke und Modems. Hinweis für Netzkabel Wenn kein Netzkabel mit dem Produkt geliefert wurde, kaufen Sie ein Kabel, das für die 72 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 87
    Teile. Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. • Schalten Sie den Server aus, und ziehen Sie alle Netzkabel ab, bevor Sie Komponenten ein- oder ausbauen, die nicht hot an einer ESD-Workstation ausführen. Steht ein solcher Intel® Server Chassis SC5600 Service Guide 73
  • Intel SC5600BASE | Service Guide - Page 88
    respectez tous les avertissements et précautions mentionnés dans ce guide avant d'installer ou de mettre à jour votre produit serveur Intel®. En cas de conflit entre les informations fournies dans ce entretenu uniquement par des techniciens qualifiés. 74 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 89
    Appendix B: Safety Information Vous devez suivre les informations de ce guide et les instructions d'assemblage des manuels de serveur pour vérifier et maintenir la d'alimentation secteur pour déconnecter l'alimentation. Veuillez réutiliser la batterie Intel® Server Chassis SC5600 Service Guide 75
  • Intel SC5600BASE | Service Guide - Page 90
    d'ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin modems reliés au système avant d'ouvrir ce dernier. 76 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 91
    panneau d'accès avec les vis ou attaches d'origine. • N'essayez pas d'accéder à l'int Le rack doit être fixé à un support inamovible pour éviter qu'il ne bascule doit être installé conformément aux instructions du fabricant. Installez les équipements dans Intel® Server Chassis SC5600 Service Guide 77
  • Intel SC5600BASE | Service Guide - Page 92
    autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. Périphériques laser Attention: Pour éviter tout risque d'exposition aux . • Retournez-les au fabricant en cas de problème. 78 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 93
    irse a las directrices de esta guía y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de los la alimentación de CA Recicle por favor la batería Intel® Server Chassis SC5600 Service Guide 79
  • Intel SC5600BASE | Service Guide - Page 94
    conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use telecomunicaciones, las redes y los módems conectados al mismo. 80 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 95
    desde la parte de abajo, con el equipo más pesado en la parte inferior del bastidor. Extraiga las piezas del equipo del bastidor de una a una. Intel® Server Chassis SC5600 Service Guide 81
  • Intel SC5600BASE | Service Guide - Page 96
    de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. 82 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 97
    Appendix B: Safety Information 简体中文 Intel Intel Intel Web UL 注意 Intel® Server Chassis SC5600 Service Guide 83
  • Intel SC5600BASE | Service Guide - Page 98
    Appendix B: Safety Information ITE ITE 场地选择 5V 84 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 99
    Appendix B: Safety Information Intel® Server Chassis SC5600 Service Guide 85
  • Intel SC5600BASE | Service Guide - Page 100
    Appendix B: Safety Information ESD) ESD ESD ESD ESD 其他危险 替换电池 86 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 101
    Appendix B: Safety Information Intel® Server Chassis SC5600 Service Guide 87
  • Intel SC5600BASE | Service Guide - Page 102
    the covers to the chassis with the screws removed earlier, and tighten them firmly. 4. Insert and lock the padlock to the system to prevent unauthorized access inside the system. 5. Connect all external cables and the AC power cord(s) to the system. 88 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 103
    Assembly Safety Instructions A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges on some board and chassis parts. Contact Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Server Chassis SC5600 Service Guide 89
  • Intel SC5600BASE | Service Guide - Page 104
    Appendix C: Installation/Assembly Safety Instructions SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, hrleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird 90 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 105
    Appendix C: Installation/Assembly Safety Instructions Français Le bloc d'alimentation de ce produit ne contient aucune pièce pouvant être réparée aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. Intel® Server Chassis SC5600 Service Guide 91
  • Intel SC5600BASE | Service Guide - Page 106
    me type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. L' tant le seul moyen de mettre le système hors tension). 92 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 107
    Español Appendix C: Installation/Assembly Safety Instructions El usuario debe abstenerse de manipular los componentes de la fuente de alimentación de piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores. Intel® Server Chassis SC5600 Service Guide 93
  • Intel SC5600BASE | Service Guide - Page 108
    Appendix C: Installation/Assembly Safety Instructions Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pilas acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. 94 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 109
    Appendix C: Installation/Assembly Safety Instructions Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell'alimentazione di e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Intel® Server Chassis SC5600 Service Guide 95
  • Intel SC5600BASE | Service Guide - Page 110
    Appendix C: Installation/Assembly Safety Instructions Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto. ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. 96 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 111
    support+ on Intel® server boards, server chassis, server RAID controller cards, and Intel® Server Management. Warranty Information Connect to Intel's website to obtain warranty information. + Requires login to the Reseller Site to obtain the 24x7 Number. Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 112
    at http://support.intel.com/support/motherboards/server/chassis/sc5600/. For the fastest service, please submit your form via the Internet. Customer Contact Information: Customer Support Case#: Intel® Server Board or System: (Example: S55200HC, S5520SC) Server Chassis: (Example SC5600. If third
  • Intel SC5600BASE | Service Guide - Page 113
    Part Number DRAM Part Number On Intel tested list? Add-in adapters (Example: NICs, Management Adapters, Serial Expansion Cards, PCIExpress* Adapters, RAID Controllers, SCSI Controllers, and so on): Type Slot Manufacturer Model Firmware Intel® Server Chassis SC5600 Service Guide 99
  • Intel SC5600BASE | Service Guide - Page 114
    RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks & RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): 100 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 115
    BBU part number: Detailed description of issue: Appendix E: Intel® Server Issue Report Form Troubleshooting tried: Steps to replicate the issue: Intel® Server Chassis SC5600 Service Guide 101
  • Intel SC5600BASE | Service Guide - Page 116
    Appendix E: Intel® Server Issue Report Form Issue impact statements: Do you have any potential Intel system, or component purchases that this issue is holding up? If yes, below. *All other brands and names are property of their respective owners. 102 Intel® Server Chassis SC5600 Service Guide
  • Intel SC5600BASE | Service Guide - Page 117
    Intel's publicly available specifications for a period of three (3) years after the date the Product was purchased from an Intel Warranty, Intel, at its option, will: problems with electrical power, usage not in accordance with product instructions Intel® Server Chassis SC5600 Service Guide 103
  • Intel SC5600BASE | Service Guide - Page 118
    (http://www.intel.com/), call your local distributor or an Intel Customer Support representative. See "Getting Help" for telephone numbers. Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. 104 Intel® Server Chassis SC5600 Service Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

Intel
®
Server Chassis SC5600 Service
Guide
A Guide for Technically Qualified Assemblers of Intel
®
identified
Subassemblies/Products
Order Number: E39533-003