Intel SC5600BASE Service Guide - Page 36
Removing and Installing Hot Swap Fans, Intel, Server Chassis SC5600LX only
View all Intel SC5600BASE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Hardware Installations and Upgrades C A B = Figure 15. Removing a Fixed Fan 7. Install a new 92-mm or 120-mm fixed fan. 8. Connect the fan power cable to the server/workstation board. See the Quick Start User's Guide or Service Guide provided with your Intel® server/workstation board for the appropriate connection location. 9. Install the air duct if it was removed in a previous step. For instructions, see "Installing the Air Duct." 10. Plug all peripheral devices and the AC power cable into the server and then power up the server. Removing and Installing Hot Swap Fans (Intel® Server Chassis SC5600LX only) Removing Hot Swap Fans / NOTE This procedure applies only to the Intel® Server Chassis SC5600LX configurations. The Intel® Server Chassis SC5600Base and Intel® Server Chassis SC5400BRP configurations ship with fixed fans. You cannot use the hot-swap fans from the Intel® Server Chassis SC5400LX or SC5400LXi in the Intel® Server Chassis SC5600LX. 1. Observe the safety and ESD precautions at the beginning of this book. 22 Intel® Server Chassis SC5600 Service Guide