Intel SC5600BASE Service Guide - Page 37
Installing Hot Swap Fans
View all Intel SC5600BASE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Hardware Installations and Upgrades 2. Remove the chassis cover. For instructions, see "Removing the Chassis Cover." 3. Press the latch on the fan (see letter "A" in Figure 16) and pull on the handle to remove the hot swap fan from the chassis. 4. For removal of the remaining hot swap fans, repeat Step 3. Figure 16. Removing Hot Swap Fan Installing Hot Swap Fans / NOTE This procedure applies only to the Intel® Server Chassis SC5600LX configurations. The Intel® Server Chassis SC5600Base and Intel® Server Chassis SC5400BRP configurations ship with fixed fans. You cannot use the hot-swap fans from the Intel® Server Chassis SC5400LX or SC5400LXi in the Intel® Server Chassis SC5600LX. 1. Observe the safety and ESD precautions at the beginning of this book. 2. Remove the chassis cover if it was not removed in a previous step. For instructions, see "Removing the Chassis Cover." 3. Insert the hot swap fan into the chassis until it latches into place. 4. For insertion of the remaining hot swap fans, repeat Step 3. Intel® Server Chassis SC5600 Service Guide 23