HEADER REC Function

Page 29 highlights

SHOOTING OPERATION HEADER REC Function When the REC/VTR trigger button is pressed while the STOP button is pressed, this function first records the color bar video and the test tone (1 kHz sine-wave) of the built-in signal generator at the beginning of the tape. Then it records the black video signal and the mute audio signal for the duration specified in advance. When the recording is completed, the unit enters the RecordStandby mode. The time code value at the Record-Standby position becomes the time code specified in advance. (HEADER REC function) • Settings related to the HEADER REC function, such as whether the HEADER REC function should be enabled, the HEADER REC execution duration, and the time code value setting when the HEADER REC recording is completed, etc., are made on the HEADER REC menu screen. • The HEADER REC function is executed under the following circumstances: CAM/VTR button: Set to CAM mode. In the Record-Standby or Stop mode Tape beginning HEADER REC (Example) 30 sec Record-Standby mode (Example) 30 sec Normal recording Color bar video signal Test tone (1 kHz) (Setting range: 0 to 99 sec) Time code, user's bits recording Black video signal Mute audio (No sound) (Setting range: 0 to 99 sec) Time code, user's bits recording Time code: The value specified on the HEADER REC menu screen- HEADER REC time (Example) 23:59:00:00 User's bits: The value specified for the UB DATA item on the HEADER REC menu screen. Time code: The value specified on the HEADER REC menu screen. (Example) 00:00:00:00 User's bits: The value specified for the UB PRESET item on the TC/UB/ CLOCK menu screen. (only when set to REC RUN or FREE RUN mode) „ HEADER REC menu screen contents Item START KEY TC DATA UB DATA BARS TIME BLACK TIME PAGE BACK Function/Initial Setting Sets whether the HEADER REC operation should be executed when the REC/VTR trigger button is pressed while the STOP button is pressed. DISABLE : HEADER REC operation is not executed. STOP+REC : HEADER REC operation is executed. Sets the time code value for the point when the Record-Standby mode is engaged following completion of HEADER REC. EXECUTE : Confirms the set time code. ZERO PRESET: Resets all time codes to zero "0". CANCEL : Clears the set time code. The frame mode is set depending on the setting in the DROP/NON DROP item on the TC/UB/CLOCK menu screen. * The time code value at the point when the Record-Standby mode is engaged may differ some frames from the value set for this item. Sets the user's bits of the HEADER REC section. EXECUTE : Confirms the set user's bits. ZERO PRESET: Resets all user's bits data to zero "0". CANCEL : Clears the set user's bits. MEMO The user's bits for the normal recording section are set on the TC/UB/CLOCK menu screen. Sets the duration (seconds) in which the color bar signal and test tone (1 kHz) is recorded during HEADER REC. (1-sec steps) [Initial Setting: 0SEC - 30SEC - 99SEC] Sets the duration (seconds) in which the black signal is recorded during HEADER REC. (1-sec steps) [Initial Setting: 0SEC - 30SEC - 99SEC] The TC/UB/CLOCK menu screen returns when the SHUTTER dial is pressed. 52 TC/UB/CLOCK menu screen HEADER REC menu screen Cursor Item Set value During HEADER REC • The menu screen is not displayed during HEADER REC recording. „ How to set the HEADER REC menu screen 1. Display the HEADER REC menu screen. 1Select the TC/UB/CLOCK.. item on the TOP MENU screen. 2Select the HEADER REC item on the TC/UB/CLOCK menu screen. SHOOTING OPERATION 2. Setting the HEADER REC menu screen. 1Select the menu item. Rotate the SHUTTER dial to align the cursor (K) with the item to be set, and then press the SHUTTER dial. • The setting area of the selected item starts blinking. 2Changing the setting value. Rotate the SHUTTER dial to change the setting, and then press the SHUTTER dial. „ In the case of the TC DATA item and the UB DATA item, the blinking digit position moves when the SHUTTER dial is pressed. When the SHUTTER dial is rotated, the value of the blinking digit changes. After all the digits have been set and the SHUTTER dial is pressed, EXECUTE starts blinking. Press the SHUTTER dial once more to confirm the set value. 3. To terminate the setting, press the STATUS button. „ Executing the HEADER REC Function The START KEY item on the HEADER REC menu screen should be set to STOP+REC. 1. Load the cassette and engage the Record-Standby mode or the Stop mode. 2. While pressing the STOP button, press the REC/VTR trig- ger button. • The tape automatically rewinds to the beginning, and HEADER REC operation starts from the beginning of the tape. After HEADER REC recording is performed for the specified duration only, the Record-Standby mode is engaged automatically. • During HEADER REC recording, "HEADER REC" is shown (blinking) on the LCD monitor and in the viewfinder. 3. After HEADER REC recording is completed and the Record-Standby mode is engaged, normal recording starts when you press the REC/VTR trigger button. • When the TC GENE. switch is set to either REC or REGEN, the time code value at the start of the HEADER REC menu screen. MEMO • To stop during HEADER REC operation, press the REC/ VTR trigger button or the Stop button. • The HEADER REC menu screen cannot be opened during HEADER REC recording. • HEADER REC operation is accepted even during loading of the cassette tape. • The test tone (1 kHz sine-wave) recorded in the color bar section will be recorded unrelated to the setting for the TEST TONE item on the AUDIO/MIC [1/2] menu screen. • The time code preset on the TC/UB/CLOCK menu screen becomes invalid when HEADER REC recording is performed. • The user's bits following completion of HEADER REC recording will be the user's bits value set on the TC/UB/ CLOCK menu screen. • The running of the time code following completion of HEADER REC recording will be in accordance with the setting of the TC GENE. switch. FREE RUN: Continuous running. REC RUN or REGEN: Runs only during REC. • Camera images are not output to the LCD monitor, viewfinder or video output during REW mode when the HEADER REC operation begins. 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

52
SHOOTING OPERATION
HEADER REC Function
When the REC/VTR trigger button is pressed while the STOP button is pressed, this function first records the color bar video and
the test tone (1 kHz sine-wave) of the built-in signal generator at the beginning of the tape. Then it records the black video signal
and the mute audio signal for the duration specified in advance. When the recording is completed, the unit enters the Record-
Standby mode. The time code value at the Record-Standby position becomes the time code specified in advance. (HEADER
REC function)
Settings related to the HEADER REC function, such as whether the HEADER REC function should be enabled, the HEADER
REC execution duration, and the time code value setting when the HEADER REC recording is completed, etc., are made on
the HEADER REC menu screen.
The HEADER REC function is executed under the following circumstances:
CAM/VTR button: Set to CAM mode.
In the Record-Standby or Stop mode
HEADER REC menu screen contents
Item
Function/Initial Setting
START KEY
Sets whether the HEADER REC operation should be executed when the REC/VTR trigger button is pressed while the
STOP button is pressed.
DISABLE
:
HEADER REC operation is not executed.
STOP+REC
:
HEADER REC operation is executed.
TC DATA
Sets the time code value for the point when the Record-Standby mode is engaged following completion of HEADER
REC.
EXECUTE
:
Confirms the set time code.
ZERO PRESET:
Resets all time codes to zero “0”.
CANCEL
:
Clears the set time code.
The frame mode is set depending on the setting in the DROP/NON DROP item on the TC/UB/CLOCK menu screen.
* The time code value at the point when the Record-Standby mode is engaged may differ some frames from the value
set for this item.
UB DATA
Sets the user’s bits of the HEADER REC section.
EXECUTE
:
Confirms the set user’s bits.
ZERO PRESET:
Resets all user’s bits data to zero “0”.
CANCEL
:
Clears the set user’s bits.
MEMO
The user’s bits for the normal recording section are set on the TC/UB/CLOCK menu screen.
BARS TIME
Sets the duration (seconds) in which the color bar signal and test tone (1 kHz) is recorded during HEADER REC. (1-sec
steps)
[Initial Setting: 0SEC - 30SEC - 99SEC]
BLACK TIME
Sets the duration (seconds) in which the black signal is recorded during HEADER REC. (1-sec steps)
[Initial Setting: 0SEC - 30SEC - 99SEC]
PAGE BACK
The TC/UB/CLOCK menu screen returns when the SHUTTER dial is pressed.
Tape beginning
HEADER REC
Record-Standby mode
Normal recording
(Example) 30 sec
(Example) 30 sec
Color bar video signal
Test tone (1 kHz)
(Setting range: 0 to 99 sec)
Black video signal
Mute audio (No sound)
(Setting range: 0 to 99 sec)
Time code, user’s bits recording
Time code, user’s bits recording
Time code:
The value specified on the HEADER
REC menu screen- HEADER REC time
(Example) 23:59:00:00
Time code:
The value specified on the HEADER
REC menu screen.
(Example) 00:00:00:00
User’s bits:
The value specified for the UB
DATA item on the HEADER REC
menu screen.
User’s bits:
The value specified for the UB
PRESET item on the TC/UB/
CLOCK menu screen.
(only when set to REC RUN or
FREE RUN mode)
53
SHOOTING OPERATION
The menu screen is not displayed during HEADER REC
recording.
How to set the HEADER REC menu screen
1.
Display the HEADER REC menu screen.
1
Select the TC/UB/CLOCK.. item on the TOP MENU
screen.
2
Select the HEADER REC item on the TC/UB/CLOCK
menu screen.
2.
Setting the HEADER REC menu screen.
1
Select the menu item.
Rotate the SHUTTER dial to align the cursor (
K
) with
the item to be set, and then press the SHUTTER dial.
The setting area of the selected item starts blinking.
2
Changing the setting value.
Rotate the SHUTTER dial to change the setting, and
then press the SHUTTER dial.
In the case of the TC DATA item and the UB DATA item,
the blinking digit position moves when the SHUTTER
dial is pressed. When the SHUTTER dial is rotated, the
value of the blinking digit changes. After all the digits
have been set and the SHUTTER dial is pressed, EXE-
CUTE starts blinking. Press the SHUTTER dial once
more to confirm the set value.
3.
To terminate the setting, press the STATUS button.
Executing the HEADER REC Function
The START KEY item on the HEADER REC menu screen
should be set to STOP+REC.
1.
Load the cassette and engage the Record-Standby mode
or the Stop mode.
2.
While pressing the STOP button, press the REC/VTR trig-
ger button.
The tape automatically rewinds to the beginning, and
HEADER REC operation starts from the beginning of
the tape.
After HEADER REC recording is performed for the
specified duration only, the Record-Standby mode is
engaged automatically.
During HEADER REC recording, “HEADER REC” is
shown (blinking) on the LCD monitor and in the viewfinder.
3.
After HEADER REC recording is completed and the
Record-Standby mode is engaged, normal recording
starts when you press the REC/VTR trigger button.
When the TC GENE. switch is set to either REC or
REGEN, the time code value at the start of the
HEADER REC menu screen.
MEMO
To stop during HEADER REC operation, press the REC/
VTR trigger button or the Stop button.
The HEADER REC menu screen cannot be opened dur-
ing HEADER REC recording.
HEADER REC operation is accepted even during loading
of the cassette tape.
The test tone (1 kHz sine-wave) recorded in the color bar
section will be recorded unrelated to the setting for the
TEST TONE item on the AUDIO/MIC [1/2] menu screen.
The time code preset on the TC/UB/CLOCK menu screen
becomes invalid when HEADER REC recording is per-
formed.
The user’s bits following completion of HEADER REC
recording will be the user’s bits value set on the TC/UB/
CLOCK menu screen.
The running of the time code following completion of
HEADER REC recording will be in accordance with the
setting of the TC GENE. switch.
FREE RUN: Continuous running.
REC RUN or REGEN: Runs only during REC.
Camera images are not output to the LCD monitor, view-
finder or video output during REW mode when the
HEADER REC operation begins.
TC/UB/CLOCK menu screen
HEADER REC menu screen
Cursor
Item
Set value
During HEADER REC