JVC GYHD110U Instructions - Page 40

LCD/VF [1/3] Menu Screen, LCD/VF [2/3] Menu Screen - batteries

Page 40 highlights

MENU SCREENS LCD/VF [1/3] Menu Screen The LCD/VF menu screen consists of three screens. (1/3 screen, 2/3 screen, 3/3 screen) The LCD/VF [1/3] menu screen can only be set in camera mode. In VTR mode, this screen consists of two screens. (1/2 screen, 2/2 screen) Item Function/Setting (bold characters indicate initial settings) ZEBRA Switches the luminance level of the subject sections where the zebra pattern is displayed. 60-70% : Zebra pattern is displayed in sections with luminance levels between 60% and 70%. 70-80% : Zebra pattern is displayed in sections with luminance levels between 70% and 80%. 85-95% : Zebra pattern is displayed in sections with luminance levels between 85% and 95%. OVER95% : Zebra pattern is displayed in sections with luminance levels over 95%. OVER100% : Zebra pattern is displayed in sections with luminance levels over 100% F. NO/IRIS IND. Selects whether or not the F-number of the lens iris/iris level mark is displayed in the status display on the LCD mon- itor or in the viewfinder. (STATUS 1 screen) OFF : F-number and iris level mark is not displayed. F.NO : F-number is displayed. F.NO+IND. : F-number and iris level mark is displayed. FILTER Selects whether or not the FILTER position of the unit is displayed in the status display on the LCD monitor or in the viewfinder. (STATUS 1 screen) OFF : FILTER position is not displayed. ON : FILTER position is displayed. SAFETY ZONE*1 Selects whether or not the safety zone is shown on the LCD monitor or in the viewfinder together with the form of the safety zone indication. OFF : Not displayed 4:3 : 4:3 zone is displayed. 14:9 : 14:9 zone is displayed. 16:9 : 16:9 zone is displayed. 16:9+4:3 : 16:9 zone and 4:3 zone are display mixed. (This cannot be selected when DV format is set.) CENTER MARK*1 Sets whether or not a center mark is displayed when the safety zone is displayed. ON : Center mark is displayed. OFF : Center mark is not displayed. MEMO When the SAFETY ZONE item is set to OFF, "- - -" is indicated and this item cannot be selected. FOCUS ASSIST Sets the display color for focusing when running the FOCUS ASSIST function. BLUE : Displays the area of focus in blue. RED : Displays the area of focus in red. GREEN : Displays the area of focus in green. LEVEL Sets the display range of the focal area when the FOCUS ASSIST function is in use. LOW : Displays the focal area narrower than MIDDLE. MIDDLE : Displays the focal area in normal setting. HIGH : Displays the focal area wider than MIDDLE. LCD MIRROR MODE Sets the image display method when the LCD monitor is in counterview position. NORMAL : Image is displayed without inverting. MIRROR : Inverted image is displayed. MEMO MIRROR setting is disabled when color bar is displayed or status is in magnified size. X See "Outputting color bars" on page 88. X See "Magnified Status Indications on the LCD Monitor" on page 26. NEXT PAGE When you display the LCD/VF [2/3] menu screen, move the cursor to this position and press the SHUTTER dial. PAGE BACK When the cursor is in this position, press the SHUTTER dial to return to the TOP MENU screen. *1 SAFTY ZONE and CENTER MARK will not be displayed when the camcorder is in VTR mode (PLAY, STL, FWD, REV). MENU SCREENS LCD/VF [2/3] Menu Screen [1/2] screen is displayed in the VTR mode. Item VIDEO FORMAT TAPE REMAIN TC/UB AUDIO BATTERY INFO NEXT PAGE PAGE BACK Function/Setting (bold characters indicate initial settings) Selects whether to display the video format in the status display on the LCD monitor or the viewfinder. (Camera mode: STATUS 1 screen, VTR mode: STATUS screen) ON : Displays the video format. OFF : Does not display the video format. In camera mode : Displays the video format set in the REC item on the VIDEO FORMAT menu screen. In VTR mode : Displays the video format recorded on the playback tape or the video format input from the IEEE1394 connector. Selects whether or not the remaining tape time (minutes) is shown in the status display on the LCD monitor or in the viewfinder. (Camera mode: STATUS 1 screen, VTR mode: STATUS screen) ON : Displayed. OFF : Not displayed. Selects whether or not the time code or user's bits data should be shown in the status display on the LCD monitor or in the viewfinder. (Camera mode: STATUS 1 screen, VTR mode: STATUS screen) OFF : Not displayed. ON : Displayed. * Whether the time code or user's bits data is shown is selected with the TC DISPLAY switch. Selects whether the audio level meters should be shown in the status display on the LCD monitor and the viewfinder screen. (Camera mode: STATUS 1 screen, VTR mode: STATUS screen) OFF : Not displayed. ON : Displayed. For setting the status display method when loading the Anton-Bauer Battery. The status will be displayed on the LCD screen and the viewfinder screen. (In camera mode, only displayed when in status 1 screen.) VOLTAGE : Indicates battery voltage in 0.1 V steps [V] CAPA% : Remaining battery is shown in percentage [%] TIME : Remaining battery is shown in minutes [min] For batteries other than Anton-Bauer type, only VOLTAGE display is available regardless of the selection. MEMO • When TIME or CAPA is selected, the battery indicator displayed before the value changes depending on the remaining battery level. }: 12 % or less |: 12 % to less than 50 % {: 50 % or more • When remaining battery level becomes less than 12%, the display changes to "} RES". • When CALIBRATION is required from the battery, the display switches between TIME(CAPA%) display (30 seconds) and "} CAL" display (2 seconds) repeatedly. • For CALIBRATION, refer to the instruction manual of Anton-Bauer Battery. • Please use the remaining battery level and remaining time as a reference for shooting duration. Camera mode: To display the LCD/VF [3/3] menu screen, move the cursor to this position and press the SHUTTER dial. VTR mode: To display the LCD/VF [2/2] menu screen, move the cursor to this position and press the SHUTTER dial. Camera mode: When the cursor is in this position, press the SHUTTER dial to return to the LCD/VF [1/3] menu screen. VTR mode: When the cursor is in this position, press the SHUTTER dial to return to the TOP MENU screen. 74 75

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

74
MENU SCREENS
LCD/VF [1/3] Menu Screen
The LCD/VF menu screen consists of three screens. (1/3 screen, 2/3 screen, 3/3 screen)
The LCD/VF [1/3] menu screen can only be set in camera mode.
In VTR mode, this screen consists of two screens. (1/2 screen, 2/2 screen)
*1
SAFTY ZONE and CENTER MARK will not be displayed when the camcorder is in VTR mode (PLAY, STL, FWD, REV).
Item
Function/Setting (bold characters indicate initial settings)
ZEBRA
Switches the luminance level of the subject sections where the zebra pattern is displayed.
60-70%
:
Zebra pattern is displayed in sections with luminance levels between 60% and 70%.
70-80%
:
Zebra pattern is displayed in sections with luminance levels between 70% and 80%.
85-95%
:
Zebra pattern is displayed in sections with luminance levels between 85% and 95%.
OVER95%
:
Zebra pattern is displayed in sections with luminance levels over 95%.
OVER100%
:
Zebra pattern is displayed in sections with luminance levels over 100%
F. NO/IRIS IND.
Selects whether or not the F-number of the lens iris/iris level mark is displayed in the status display on the LCD mon-
itor or in the viewfinder. (STATUS 1 screen)
OFF
:
F-number and iris level mark is not displayed.
F.NO
:
F-number is displayed.
F.NO+IND.
:
F-number and iris level mark is displayed.
FILTER
Selects whether or not the FILTER position of the unit is displayed in the status display on the LCD monitor or in the
viewfinder. (STATUS 1 screen)
OFF
:
FILTER position is not displayed.
ON
:
FILTER position is displayed.
SAFETY ZONE*1
Selects whether or not the safety zone is shown on the LCD monitor or in the viewfinder together with the form of
the safety zone indication.
OFF
:
Not displayed
4:3
:
4:3 zone is displayed.
14:9
:
14:9 zone is displayed.
16:9
:
16:9 zone is displayed.
16:9+4:3
:
16:9 zone and 4:3 zone are display mixed. (This cannot be selected when DV format is set.)
CENTER MARK*1
Sets whether or not a center mark is displayed when the safety zone is displayed.
ON
:
Center mark is displayed.
OFF
:
Center mark is not displayed.
MEMO
When the SAFETY ZONE item is set to OFF, “- - -” is indicated and this item cannot be selected.
FOCUS ASSIST
Sets the display color for focusing when running the FOCUS ASSIST function.
BLUE
:
Displays the area of focus in blue.
RED
:
Displays the area of focus in red.
GREEN
:
Displays the area of focus in green.
LEVEL
Sets the display range of the focal area when the FOCUS ASSIST function is in use.
LOW
:
Displays the focal area narrower than MIDDLE.
MIDDLE
:
Displays the focal area in normal setting.
HIGH
:
Displays the focal area wider than MIDDLE.
LCD MIRROR MODE
Sets the image display method when the LCD monitor is in counterview position.
NORMAL
:
Image is displayed without inverting.
MIRROR
:
Inverted image is displayed.
MEMO
MIRROR setting is disabled when color bar is displayed or status is in magnified size.
X
See “Outputting color bars” on page 88.
X
See “Magnified Status Indications on the LCD Monitor” on page 26.
NEXT PAGE
When you display the LCD/VF [2/3] menu screen, move the cursor to this position and press the SHUTTER dial.
PAGE BACK
When the cursor is in this position, press the SHUTTER dial to return to the TOP MENU screen.
75
MENU SCREENS
LCD/VF [2/3] Menu Screen
[1/2] screen is displayed in the VTR mode.
Item
Function/Setting (bold characters indicate initial settings)
VIDEO FORMAT
Selects whether to display the video format in the status display on the LCD monitor or the viewfinder.
(Camera mode: STATUS 1 screen, VTR mode: STATUS screen)
ON
:
Displays the video format.
OFF
:
Does not display the video format.
In camera mode
:
Displays the video format set in the REC item on the VIDEO FORMAT menu screen.
In VTR mode
: Displays the video format recorded on the playback tape or the video format input from the
IEEE1394 connector.
TAPE REMAIN
Selects whether or not the remaining tape time (minutes) is shown in the status display on the LCD monitor or in the
viewfinder.
(Camera mode: STATUS 1 screen, VTR mode: STATUS screen)
ON
: Displayed.
OFF
: Not displayed.
TC/UB
Selects whether or not the time code or user’s bits data should be shown in the status display on the LCD monitor
or in the viewfinder.
(Camera mode: STATUS 1 screen, VTR mode: STATUS screen)
OFF
:
Not displayed.
ON
: Displayed.
* Whether the time code or user’s bits data is shown is selected with the TC DISPLAY switch.
AUDIO
Selects whether the audio level meters should be shown in the status display on the LCD monitor and the viewfinder
screen.
(Camera mode: STATUS 1 screen, VTR mode: STATUS screen)
OFF
:
Not displayed.
ON
: Displayed.
BATTERY INFO
For setting the status display method when loading the Anton-Bauer Battery.
The status will be displayed on the LCD screen and the viewfinder screen.
(In camera mode, only displayed when in status 1 screen.)
VOLTAGE
:
Indicates battery voltage in 0.1 V steps [V]
CAPA%
:
Remaining battery is shown in percentage [%]
TIME
:
Remaining battery is shown in minutes [min]
For batteries other than Anton-Bauer type, only VOLTAGE display is available regardless of the selection.
MEMO
• When TIME or CAPA is selected, the battery indicator displayed before the value changes depending on the
remaining battery level.
}
: 12 % or less
|
: 12 % to less than 50 %
{
: 50 % or more
• When remaining battery level becomes less than 12%, the display changes to “
}
RES”.
• When CALIBRATION is required from the battery, the display switches between TIME(CAPA%) display (30 sec-
onds) and “
}
CAL” display (2 seconds) repeatedly.
• For CALIBRATION, refer to the instruction manual of Anton-Bauer Battery.
• Please use the remaining battery level and remaining time as a reference for shooting duration.
NEXT PAGE
Camera mode:
To display the LCD/VF [3/3] menu screen, move the cursor to this position and press the SHUTTER dial.
VTR mode:
To display the LCD/VF [2/2] menu screen, move the cursor to this position and press the SHUTTER dial.
PAGE BACK
Camera mode:
When the cursor is in this position, press the SHUTTER dial to return to the LCD/VF [1/3] menu screen.
VTR mode:
When the cursor is in this position, press the SHUTTER dial to return to the TOP MENU screen.