Lexmark E330 Service Manual - Page 82
Action, Step 1: Continuity, Step 2: No continuity
View all Lexmark E330 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
4505 Fuser service check (continued) FRU Lamp cable LVPS/HVPS Fuser Action Unplug the printer and disconnect the fuser lamp cable plug from the LVPS/HVPS board connector CN102. Check for continuity across the fuser lamp by checking across the connector pins. • If there is continuity, go to Step 1: Continuity. • If there is no continuity, go to Step 2: No continuity. Step 1: Continuity Turn the printer on with only the fuser power disconnected. Measure the voltage at connector CN2 on the LVPS/HVPS. It should match the line voltage. • If line voltage is not present, see "LVPS/HVPS service check" on page 2-57 for more information. Make sure the fuser thermistor is correctly connected to the controller board. If the problem persists, disconnect the thermistor cable at J15 and check for less than +5 V dc on pin 1. Pin 2 should be ground. • If line voltage is incorrect on pin 1, see "Controller card service check" on page 2-49 for more information. Step 2: No continuity Check the lamp cable for continuity. • If correct, replace the fuser. • If incorrect, replace the lamp cable. 2-54 Service Manual