Lexmark E330 Service Manual - Page 86
Main motor service check
View all Lexmark E330 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
4505 Main motor service check FRU Main motor cable LVPS/HVPS Controller card Warning: Do not replace the operator panel and controller card at the same time. Each card contains the printer settings. When either of these cards is new, it obtains the settings from the other card. Settings are lost when both are new and replaced at the same time. Action Verify +24 V dc at J9, pin 8 and +5 V dc at pin 1 (controller card). Verify ground at pins 2 and 7 for both the card and cable. • If these voltages are correct, check the main motor cable for continuity. - Remove rear cover to access connector on motor. - If continuity exists on each wire, call next level of service. - If continuity does not exist on one or more of the wires, replace the motor cable. • If these voltages are not correct, see the "LVPS/HVPS service check" on page 2-57 or replace the controller card. Note: The main motor is not a service part. 2-58 Service Manual