Panasonic 55 Professional Display for Entry-Level Digital Signage Operating In - Page 55

Network status], DIGITAL LINK mode] LF80 series only

Page 55 highlights

[IP address]: (IP address display and setting) Enter an IP address when DHCP server is not used. [Subnet mask]: (Subnet mask display and setting) Enter a Subnet mask when DHCP server is not used. [Gateway]: (Gateway address display and setting) Enter a gateway address when DHCP server is not used. Note ● When [DHCP] is set to [On], the IP address, etc. will be displayed in grey. Entering numbers IP address I192.168. 0. 8 1. Select the address and press . 2. Select digits with . 3. Change numbers with . 4. Press . You can cancel the change by pressing . Select [Save] and press . Save the current network Setup. Note ● To use a DHCP server, make sure the DHCP server is started. ● Contact your network administrator for details on [IP address], [Subnet mask] and [Gateway]. ● Shipping condition [DHCP]: Off [IP address]: 192.168.0.8 [Subnet mask]: 255.255.255.0 [Gateway]: 192.168.0.1 [Port] Set the port number used for command control. Select [Port] and press to set the number. ● The available setting range is 1024 - 65535. ● Entering numbers (see page 55) Note ● When the PJLink protocol is used, the port setting is not necessary. [MAC address] Displays the MAC address of this unit. ■■[Network status] Checks the current Network settings status. Network status DHCP IP address Subnet mask Gateway MAC address Off 192. 168. 0. 8 255. 255. 255. 0 192. 168. 0. 1 12:34:56:78:9A:BC ■■[DIGITAL LINK mode] (LF80 series only) Switches communication method of DIGITAL LINK terminal. [Auto]: Communication method is selected automatically. [DIGITAL LINK]: Communication method is fixed to DIGITAL LINK. [Ethernet]: Communication method is fixed to Ethernet. [Long reach]: Communication method is fixed to Long reach. Modes allowing communication : Valid ― : Invalid Settings Auto For DIGITAL LINK For Long reach Communication validity Picture transmission Ethernet 100 m 150 m RS232C ― ― For Ethernet ― ― ― DIGITAL LINK ― Long reach ― Ethernet ―― ― Note ● When connected with the [Long reach] communication method, the maximum transmission distance is 150 m. In this case, this unit can receive the signals of up to 1080/60p (148.5 MHz). ● If the communication method of the twisted pair cable transmitter is set to [Long reach], set [DIGITAL LINK mode] to [Auto]. Then, connection is enabled with the [Long reach] communication method. When connecting with the separately sold DIGITAL LINK Switcher (ET-YFB200G) with the [Long reach] communication method, set [DIGITAL LINK mode] to [Long reach]. English 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

55
English
[IP address]:
(IP address display and setting)
Enter an IP address when DHCP server is not used.
[Subnet mask]:
(Subnet mask display and setting)
Enter a Subnet mask when DHCP server is not
used.
[Gateway]:
(Gateway address display and setting)
Enter a gateway address when DHCP server is not
used.
Note
When [DHCP] is set to [On], the IP address, etc. will
be displayed in grey.
Entering numbers
I
1
92.168.
0.
8
IP address
1.
Select the address and press <ENTER>.
2.
Select digits with
.
3.
Change numbers with
.
4.
Press <ENTER>.
You can cancel the change by pressing
<RETURN>.
Select [Save] and press <ENTER>.
Save the current network Setup.
Note
To use a DHCP server, make sure the DHCP
server is started.
Contact your network administrator for details on
[IP address], [Subnet mask] and [Gateway].
Shipping condition
[DHCP]: Off
[IP address]: 192.168.0.8
[Subnet mask]: 255.255.255.0
[Gateway]: 192.168.0.1
[Port]
Set the port number used for command control.
Select [Port] and press <ENTER> to set the number.
The available setting range is 1024 - 65535.
Entering numbers (see page 55)
Note
When the PJLink protocol is used, the port setting is
not necessary.
[MAC address]
Displays the MAC address of this unit.
[Network status]
Checks the current Network settings status.
192. 168.
0.
1
255. 255. 255.
0
192. 168.
0.
8
12:34:56:78:9A:BC
Network status
DHCP
IP address
Subnet mask
Gateway
MAC address
Off
[DIGITAL LINK mode] (LF80 series only)
Switches communication method of DIGITAL LINK
terminal.
[Auto]:
Communication method is selected automatically.
[DIGITAL LINK]:
Communication method is fixed to DIGITAL LINK.
[Ethernet]:
Communication method is fixed to Ethernet.
[Long reach]:
Communication method is fixed to Long reach.
Modes allowing communication
:
Valid
―:
Invalid
Settings
Communication validity
Picture
transmission
Ethernet
RS-
232C
100 m
150 m
Auto
For
DIGITAL
LINK
For Long
reach
For
Ethernet
DIGITAL LINK
Long reach
Ethernet
Note
When connected with the [Long reach]
communication method, the maximum
transmission distance is 150 m. In this case, this
unit can receive the signals of up to 1080/60p
(148.5 MHz).
If the communication method of the twisted
pair cable transmitter is set to [Long reach], set
[DIGITAL LINK mode] to [Auto]. Then, connection
is enabled with the [Long reach] communication
method.
When connecting with the separately sold DIGITAL
LINK Switcher (ET-YFB200G) with the [Long
reach] communication method, set [DIGITAL LINK
mode] to [Long reach].