Panasonic PT52LCX66 Service Manual - Page 18

CN9502 From LCD Drive P.C.B. - thermal fuse

Page 18 highlights

PT-52LCX66 / PT-56LCX66 / PT-61LCX66 / PT-52LCX16 / PT-56LCX16 After servicing, make sure that all wires, leads, and clampers are placed in their original position. It is important for the best operation of the unit. Note: Use extreme care especially for the following. CN2705 (To Iris P.C.B.) CN2301 CN2702 (From (From Thermistor Fan 2) 2 P.C.B.) CN2701 (From Fan 1) GND Wire of LVDS Cable CN2303 (No connection) CN2502 CN2704 CN2703 CN2501 (From Main (From Main (From (From Cover P.C.B.) P.C.B.) Fan 3) Switch P.C.B.) Clamper Clampers CN1522 (From Main P.C.B.) Clamper Clamper CN1001 (AC Cord) Clamper CN1514 (From Main P.C.B.) Clamper CN1520 CN1516 (From (From Base Thermal P.C.B.) Fuse) Power PCB Mount Metal CN9501 (No connection) CN9500 (From Hall-S P.C.B.) Clamper Clamper CN9502 (From LCD Drive P.C.B.) Fig. 9-3 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83

After servicing, make sure that all wires, leads, and clampers are placed in their original position. It is important for the best
operation of the unit.
Note:
Use extreme care especially for the following.
GND Wire
of LVDS Cable
Power PCB Mount Metal
CN9502 (From LCD Drive P.C.B.)
CN9500
(From Hall-S
P.C.B.)
CN2502
(From Main
P.C.B.)
Clamper
Clampers
Clamper
CN2702
(From
Fan 2)
CN2703
(From
Fan 3)
CN2501
(From Cover
Switch P.C.B.)
CN2303
(No connection)
CN2701
(From Fan 1)
CN2705
(To Iris
P.C.B.)
CN1001
(AC Cord)
CN1522
(From Main
P.C.B.)
CN1514
(From Main
P.C.B.)
CN1520
(From
Thermal
Fuse)
CN2301
(From
Thermistor
2 P.C.B.)
CN1516
(From Base
P.C.B.)
Clamper
Clamper
Clamper
Clamper
Clamper
CN9501
(No connection)
CN2704
(From Main
P.C.B.)
Fig. 9-3
PT-52LCX66 / PT-56LCX66 / PT-61LCX66 / PT-52LCX16 / PT-56LCX16
18