Sharp XE A302 XE-A302 Operation Manual in English and Spanish - Page 63
Mode switch position, Key operation, OPX/Z, X1/Z1, X2/Z2, of Various Function Selection
UPC - 074000048294
View all Sharp XE A302 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Item Total in drawer report Individual clerk report Full clerk report Mode switch position OPX/Z X1/Z1 X2/Z2 -- X1 X2 2 Reading: Key operation A X, Z -- -- L Reading: P Resetting: (The report of the current clerk) L -- X1, Z1 X2, Z2 Reading: P Resetting: L L Hourly report (full) Hourly report (by range) Daily net sales report -- X1, Z1 -- s Reading: -- X1 -- Reading: Start time (hour) -- s -- X2, Z2 Reading: P Resetting: @ End time (hour) P Resetting: s s s • When both sales quantities and sales amounts are zero, printing is skipped. If you do not want to skip, change the programming. (Refer to "Print format" of "Various Function Selection Programming 1".) • "X" represents read symbol and "Z" represents reset symbol in the reports. • To stop reading and resetting the PLU sales report, turn the mode switch to the MGR position. The data will not be erased when you reset. • When printing is performed continuously, the printing may be intermitted several seconds. After the intermission, the printing will be restarted. 61