Sony HDWM2100/20 Operation Manual - Page 95

FIELD, FRM12, FRM21, MOMNT, LATCH, MODE1, MODE2, Item number, Item name, Settings, panel

Page 95 highlights

Menu items in the range 900 to 999, relating to digital processing (Continued) Item number Item name 903 FREEZE MODE Settings Select the freeze mode and timing. FIELD : Freeze a video field. Field may be odd or even, according to the timing. FLD1: Freeze an odd field. FLD2: Freeze an even field. FRM12: Freeze a frame consisting of an odd field and following even field. FRM21: Freeze a frame consisting of an even field and following odd field. Odd and even fields are distinguished by the reference video signal. Changing the menu setting during a freeze does not affect the freeze image. The setting is reflected the next time a freeze is carried out. You can freeze an image using the DELETE button and TRIM+ button. For details, see menu item 904. 904 FREEZE CONTROL Determine how the buttons used to freeze an image function. FROM KEY PANEL MOMNT : Holding the DELETE button and pressing the TRIM+ button carries out a freeze. The freeze ends when the buttons are released. LATCH: Holding the DELETE button and pressing the TRIM+ button carries out a freeze. The freeze continues even after the buttons are released. • To update the freeze image Hold the DELETE button and press the TRIM+ button again. • To end the freeze Hold the DELETE button and press the TRIM- button. 905 AUTO FREEZE CONTROL Set the auto freeze function operation (conditions for ending a freeze, etc.). In dynamic tracking playback (so-called variable speed, jog, shuttle, or normal play), if there is a sudden worsening of the channel condition (entry into unrecorded area), this function freezes the image. DIS : Disable the auto freeze function. MODE1: End the freeze when signals which can be played back normally are restored. MODE2: End freeze automatically on playback after stopping. • The automatic freeze mode is determined by menu item 903. • The freeze is ended immediately, regardless of the above conditions, when this unit is switched to any of the following modes: EDIT preset on Cue up 906 STOP FREEZE CONTROL Select whether or not the STOP FREEZE function should operate. DIS : Does not operate. ENA: Operates. stby: Operates only in the standby mode. 916 ACTIVE LINE 1035 Select the conversion mode for the number of active scan lines. CONVERT MODE conv : Convert the active scan lines from 1080 to 1035, without changing the (Valid only in 59.94i or aspect ratio. 29.97PsF mode.) crop: Convert the active scan lines from 1080 to 1035. Crop the top, bottom, left, and right, then stretch the image horizontally. Note This item is valid only when menu item 018 is set to 1035. 917 ACTIVE LINE 1080 Select the conversion mode for the number of active scan lines. CONVERT MODE conv : Convert the active scan lines from 1035 to 1080, without changing the (Valid only in 59.94i or aspect ratio. 29.97PsF mode.) panel: Convert the active scan lines from 1035 to 1080. Insert the 1035 lines into 1080 lines, then compress horizontally. Note This item is valid only when menu item 018 is set to 1080. (Continued) Chapter 9 Setup Menus 9-25 Chapter 9 Setup Menus

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115

Chapter 9
Setup Menus
Chapter 9
Setup Menus
9-25
Menu items in the range 900 to 999, relating to digital processing (Continued)
903
FREEZE MODE
Select the freeze mode and timing.
FIELD :
Freeze a video field. Field may be odd or even, according to the timing.
FLD1:
Freeze an odd field.
FLD2:
Freeze an even field.
FRM12:
Freeze a frame consisting of an odd field and following even field.
FRM21:
Freeze a frame consisting of an even field and following odd field.
Odd and even fields are distinguished by the reference video signal.
Changing the menu setting during a freeze does not affect the freeze image.
The setting is reflected the next time a freeze is carried out.
You can freeze an image using the DELETE button and TRIM+ button.
For details, see menu item 904.
904
FREEZE CONTROL
FROM KEY PANEL
Determine how the buttons used to freeze an image function.
MOMNT :
Holding the DELETE button and pressing the TRIM+ button carries out
a freeze. The freeze ends when the buttons are released.
LATCH:
Holding the DELETE button and pressing the TRIM+ button carries out a
freeze. The freeze continues even after the buttons are released.
• To update the freeze image
Hold the DELETE button and press the TRIM+ button again.
• To end the freeze
Hold the DELETE button and press the TRIM– button.
905
AUTO FREEZE
CONTROL
Set the auto freeze function operation (conditions for ending a freeze, etc.).
In dynamic tracking playback (so-called variable speed, jog, shuttle, or normal
play), if there is a sudden worsening of the channel condition (entry into
unrecorded area), this function freezes the image.
DIS :
Disable the auto freeze function.
MODE1:
End the freeze when signals which can be played back normally are
restored.
MODE2:
End freeze automatically on playback after stopping.
• The automatic freeze mode is determined by menu item 903.
• The freeze is ended immediately, regardless of the above conditions, when this
unit is switched to any of the following modes:
EDIT preset on
Cue up
906
STOP FREEZE
CONTROL
Select whether or not the STOP FREEZE function should operate.
DIS :
Does not operate.
ENA:
Operates.
stby:
Operates only in the standby mode.
Item number
Item name
Settings
916
ACTIVE LINE 1035
CONVERT MODE
(Valid only in 59.94i or
29.97PsF mode.)
Select the conversion mode for the number of active scan lines.
conv :
Convert the active scan lines from 1080 to 1035, without changing the
aspect ratio.
crop:
Convert the active scan lines from 1080 to 1035. Crop the top, bottom, left,
and right, then stretch the image horizontally.
Note
This item is valid only when menu item 018 is set to 1035.
917
ACTIVE LINE 1080
CONVERT MODE
(Valid only in 59.94i or
29.97PsF mode.)
Select the conversion mode for the number of active scan lines.
conv :
Convert the active scan lines from 1035 to 1080, without changing the
aspect ratio.
panel:
Convert the active scan lines from 1035 to 1080. Insert the 1035 lines into
1080 lines, then compress horizontally.
Note
This item is valid only when menu item 018 is set to 1080.
(Continued)