Toshiba Portege R500 Maintenance Manual - Page 122
E2prom Test Mac/guid/dmi
View all Toshiba Portege R500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
3 Tests and Diagnostics 3.3 Setting of the hardware configuration Subtest 2 Subtest 3 7. "Create DMIINFO TXT (Y/N) ?" is displayed. Press Y, then the DMI information (text data) is written to the Floppy disk, etc. • Setting of the HWSC • Setting of the UUID • Display of the DMI information (including UUID) After completion of the above settings, H/W configuration & DMI information are appeared in order. Check the contents and press Enter. DMI information save This is one of tools to copy the DMI information to a new PCB after replacing. This subtest saves all the DMI data in a floppy disk. DMI information recovery This is one of tools to copy the DMI information to a new PCB after replacing. This subtest writes all the DMI data in the floppy disk into the new PCB. NOTE: Since the data of UUID is updated every time when this subtest, DMI information recovery, is done, the saved UUID data is not written. Subtest 4 Subtest 5 System configuration display This subtest displays the information of the system configuration. When the following message appears, confirm the contents and press Enter. Press [Enter] key For more details on the system configuration information, refer to "3.25 System configuration". E2PROM test (MAC/GUID/DMI) It checks whether the MAC address, GUID of IEEE1394 and DMI information are written. 3-10 [CONFIDENTIAL] PORTEGE R500 Maintenance Manual (960-634)