Toshiba Portege R500 Maintenance Manual - Page 56
PPV output, PTV output, 1R5-E1V output, 1R8-B1V output
View all Toshiba Portege R500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
2 Troubleshooting Procedures 2.3 Power Supply Troubleshooting PPV output Error code Meaning 90h PPV voltage is over 1.80V when the computer is powered on/off. 91h PPV voltage is under 0.32V when the computer is powered on. 92h PPV voltage is under 0.32V when the computer is booting up. PTV output Error code Meaning A0h PTV voltage is over 1.26V when the computer is powered on/off. A1h PTV voltage is under 0.89V when the computer is powered on. A2h PTV voltage is under 0.89V when the computer is booting up. 1R5-E1V output Error code Meaning B0h 1R5-E1V voltage is over 1.80V when the computer is powered on/off. B1h 1R5-E1V voltage is under 1.275V when the computer is powered on. B2h 1R5-E1V voltage is under 1.275V when the computer is booting up. B4h 1R5-E1V voltage is under 1.275V when EV power is maintained and OUTV7=EV is designated. 1R8-B1V output Error code Meaning C0h 1R8-B1V voltage is over 2.16V when the computer is powered on/off. C1h 1R8-B1V voltage is under 1.53V when the computer is powered on. C2h 1R8-B1V voltage is under 1.53V when the computer is booting up. C4h 1R8-B1V voltage is under 1.53V when BV power is maintained and OUTV8=BV is designated. PPV output Error code Meaning D0h PPV voltage is over 1.80V when the computer is powered on/off. D1h PPV voltage is under 0.32V when the computer is powered on. D2h PPV voltage is under 0.32V when the computer is booting up. 2-10 [CONFIDENTIAL] PORTEGE R500 Maintenance Manual (960-634)