Toshiba Portege R500 Maintenance Manual - Page 78
Procedure 2, Diagnostic Test Program Execution Check
View all Toshiba Portege R500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
2 Troubleshooting Procedures Procedure 2 Diagnostic Test Program Execution Check Insert the Diagnostics Disk in the USB FDD, turn on the computer and run the test. Refer to Chapter 3, Tests and Diagnostics, for more information about the diagnostics test procedures. Floppy disk drive test error codes and their status names are listed in Table 2-6. Make sure the floppy disk is formatted correctly and that the write protect tab is disabled. If any other errors occur while executing the FDD diagnostics test, go to Check 1. Table 2-6 FDD error code and status Code 01h 02h 03h 04h 06h 08h 09h 10h 20h 40h 60h 80h EEh Status Bad command error Address mark not found Write protected Record not found Media removed DMA overrun error DMA boundary error CRC error FDC error Seek error Not drive error Time out error Write buffer error Check 1 If the following message appears, disable the write protect tab on the floppy disk. If any other message appears, perform Check 2. Write protected Check 2 Make sure the floppy disk is formatted correctly. If it is, go to Procedure 3. 2-32 [CONFIDENTIAL] PORTEGE R500 Maintenance Manual (960-634)