Toshiba T42F3F500XAMBN User Manual - Page 59

Backup History and Fault History

Page 59 highlights

TOSHIBA After the load is reduced, if the STOP/RUN key switch is in the RUN position, the UPS will automatically return to 'Inverter Operation' after a period of time. During this wait, the following screen will be displayed: - BYPASS OPERATION OUTPUT VOLTAGE=208 V CURRENT= 100/100/100 >PLEASE WAIT Or if the UPS is waiting and the STOP/RUN key switch is switched to the STOP position while the UPS is waiting, the following screen will be displayed: - BYPASS OPERATION OUTPUT VOLTAGE=208 V CURRENT= 100/100/100 >PLEASE WAIT If the STOP/RUN key switch remains in the STOP position when the UPS's 'wait' period is complete, then the following screen will be displayed: - BYPASS OPERATION OUTPUT VOLATAGE=###V CURRENT=100\100\100% DATE (DAY) TIME If the STOP/RUN key switch remains in the RUN position when the UPS's 'wait' period is complete, then the following screen will be displayed: - UPS ON-LINE OUTPUT VOLTAGE= 208 V CURRENT=100/100/99% DATE (DAY) TIME 6.21 Backup History and Fault History Pressing the MONI and F1 keys simultaneously, for a few seconds will cause the Battery Discharge Count screen to be displayed. BATT DISCHARGE COUNT # TIMES > F1: FOR DETAILS >Δ/∇: TO SCROLL Press the F1 key to display the record relating to the first discharge event. BACKUP HISTORY ( 1) #MIN##SEC VB=324V BT *PF OL >Δ/∇: EXIT F1: NEXT 4200FA CT/XT User's Manual 58

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

TOSHIBA
After the load is reduced, if the STOP/RUN key switch is in the RUN position, the UPS will
automatically return to 'Inverter Operation’ after a period of time. During this wait, the
following screen will be displayed:
-
BYPASS OPERATION
-
OUTPUT VOLTAGE=208 V
CURRENT= 100/100/100
>PLEASE WAIT
Or if the UPS is waiting and the STOP/RUN key switch is switched to the STOP position
while the UPS is waiting, the following screen will be displayed:
-
BYPASS OPERATION
-
OUTPUT VOLTAGE=208 V
CURRENT= 100/100/100
>PLEASE WAIT
If the STOP/RUN key switch remains in the STOP position when the UPS's 'wait' period is
complete, then the following screen will be displayed:
-
BYPASS OPERATION
-
OUTPUT VOLATAGE=###V
CURRENT=100\100\100%
DATE (DAY) TIME
If the STOP/RUN key switch remains in the RUN position when the UPS's 'wait' period is
complete, then the following screen will be displayed:
- UPS ON-LINE -
OUTPUT VOLTAGE= 208 V
CURRENT=100/100/99%
DATE (DAY) TIME
6.21
Backup History and Fault History
Pressing the MONI and F1 keys simultaneously, for a few seconds will cause the Battery
Discharge Count screen to be displayed.
BATT DISCHARGE COUNT
# TIMES
> F1: FOR DETAILS
>
Δ
/
: TO SCROLL
Press the F1 key to display the record relating to the first discharge event.
BACKUP HISTORY ( 1)
#MIN##SEC VB=324V
BT *PF OL
>
Δ
/
: EXIT
F1: NEXT
4200FA CT/XT User’s Manual
58