Xerox 6180N DocuSP 61xx version 3.6 - Installation Planning Guide - Page 27

Electrical requirements

Page 27 highlights

Select and prepare an installation site If passage or doorway A is: inches (mm) Table 4-3. Minimum passage widths Minimum passage B width must be: Finisher* Processor* inches (mm) inches (mm) Not separated (on casters) Separated (on casters) 29.0 (737) 30.0 (762) 31.0 (787) 32.0 (813) 34.0 (864) 36.0 (914) 38.0 (965) 40.0 (1016) 42.0 (1067) 55.5 (1410) 54.0 (1372) 52.0 (1321) 51.0 (1295) 47.0 (1194) 45.0 (1143) 43.0 (1092) 41.0 (1041) 39.0 (991) 83.0 (2108) 76.0 (1930) 73.0 (1854) 70.5 (1791) 66.5 (1690) 63.5 (1613) 61.5 (1562) 58.0 (1473) 55.0 (1397) 74.5 (1892) 64.5 (1638) 62.0 (1575) 59.5 (1511) 56.0 (1422) 53.0 (1346) 50.0 (1270) 48.0 (1219) 45.5 (1156) *The Finisher module is smaller than the separated Processor module. If there is sufficient passage width for the Processor module, there also will be sufficient clearance for the Finisher module. Electrical requirements This section describes the electrical requirements for installing one or more DocuTech printers. When selecting a location for the printer, the electrical requirements described in this section must be met. DocuTech 61xx Installation Planning Guide 4-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Select and prepare an installation site
DocuTech 61xx Installation Planning Guide
4-9
*The Finisher module is smaller than the separated Processor
module. If there is sufficient passage width for the Processor
module, there also will be sufficient clearance for the Finisher
module.
Electrical requirements
This section describes the electrical requirements for installing
one or more DocuTech printers. When selecting a location for the
printer, the electrical requirements described in this section must
be met.
Table 4-3. Minimum passage widths
If passage or doorway
A is:
inches (mm)
Minimum passage B width must be:
Finisher*
inches (mm)
Processor* inches (mm)
Not separated
(on casters)
Separated
(on casters)
29.0 (737)
55.5 (1410)
83.0 (2108)
74.5 (1892)
30.0 (762)
54.0 (1372)
76.0 (1930)
64.5 (1638)
31.0 (787)
52.0 (1321)
73.0 (1854)
62.0 (1575)
32.0 (813)
51.0 (1295)
70.5 (1791)
59.5 (1511)
34.0 (864)
47.0 (1194)
66.5 (1690)
56.0 (1422)
36.0 (914)
45.0 (1143)
63.5 (1613)
53.0 (1346)
38.0 (965)
43.0 (1092)
61.5 (1562)
50.0 (1270)
40.0 (1016)
41.0 (1041)
58.0 (1473)
48.0 (1219)
42.0 (1067)
39.0 (991)
55.0 (1397)
45.5 (1156)