Xerox 6180N DocuSP 61xx version 3.6 - Installation Planning Guide - Page 33
Environmental requirements
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Select and prepare an installation site • Standard RJ11 (6-position, 4-connector) phone wall jack. The phone wall jack must be installed within 6 feet (2 meters) of the controller. • Any third-party telephone company that may be involved must be contacted about the installation. Environmental requirements This section describes the environmental requirements for installing one or more DocuTech printers. Temperature, humidity, and altitude specifications When you select a site location for your DocuTech printer, avoid environments with extreme variations in temperature and other hazards, such as excessive dust or humidity. The recommended environmental ranges for the work area are as follows: Table 4-5. Environmental ranges for the work area Condition Temperature: Humidity: Altitude: Range Recommended: 68°Fahrenheit (F) to 76°F 20°Centigrade (C) to 24°C Minimum: 50°F (10°C) Maximum: 85°F (29°C) Recommended: 45% +10% Minimum: 15% Maximum: 85% Normal: up to 6,000 feet (1,830 m) above sea level Maximum: 9,000 feet (2,743 m) above sea level. DocuTech 61xx Installation Planning Guide 4-15