both at the calling and, All transmission phases
View all Brother International 9870 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 143 highlights
Selector No. 1 2 3 4 5 6 7 8 WSW18 (Function setting 3) Function Not used. Detection enabled time for CNG and no tone Not used. Registration of station ID Tone sound monitoring Setting and Specifications No. 2 0 0 1 1 3 0: 1: 0: 1: 40 sec. 0 sec. 5 sec. 80 sec. (No detection) 0: No. 7 0 1 1 Permitted 1: Prohibited 8 X: 0: 1: No monitoring Up to phase B at the calling station only All transmission phases both at the calling and called stations l Selectors 2 and 3: Detection enabled time for CNG and no tone After the line is connected via the machine or the external telephone, the machine can detect a CNG signal or no tone for the time length specified by these selectors. The setting specified by these selectors becomes effective only when selector 8 of WSW20 is set to "1." l Selectors 7 and 8: Tone sound monitoring These selectors set monitoring specifications of the tone sound inputted from the line. V - 31