Brother International BAS-343E Instruction Manual - English - Page 14
Adjustment of air pressure, Preparation, Adjustment method
View all Brother International BAS-343E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
3-9. Adjustment of air pressure 3. Preparation 1. Air pressure should be 0.49 MPa [5 kg/cm2]. The air pressure can be adjusted by pulling up and turning the control knob w on the integrator q. After adjustment is complete, push the control knob w downward to lock it. 2. If water stands in the bottle of the integrator q, turn the drain cock e in the direction indicated by an arrow to drain the water. 3. Adjust the air pressure for the auxiliary work clamp cylinder r to a low pressure but within the range so that the cassette plate y does not lift up when it is pressed by the cloth presser cover t during sewing. The factory default setting is 0.3 MPa (3 kgf/cm2) Adjustment method Pull up the handle i of the air regulator u and turn it to adjust. After adjusting, push the handle i down again to lock it. NOTE Open the air cock o slowly. BAS-343E 7