Draining the oil, 8-4. Cleaning the control box air inlet port, Maintenance and inspection
View all Brother International BAS-343E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
8. Maintenance and inspection 3. If using the liquid cooling tank q, fill it with silicon oil (100 cs). 4. If oil is to be mixed with the air in the needle cooler, remove the black cap and fill the oiler w with silicone oil. 8-3. Draining the oil 1. Remove and empty the waste oil container q whenever it is full. 2. After emptying the waste oil container q, screw it back into its original position. 8-4. Cleaning the control box air inlet port Use a vacuum cleaner to clean the filter in the air inlet port w of the control box q at least once a month. * If the machine is used while the air inlet port is blocked, the inside of the control box will overheat. When this happens, the overheating error code ("Ed") will be displayed and you will not be able to operate the sewing machine. BAS-343E 30