Brother International BAS-343E Instruction Manual - English - Page 40

Adjusting the needle clearance, 9-4. Adjusting the driver needle gurard

Page 40 highlights

9-3. Adjusting the needle clearance 0.01 - 0.08mm 9. Standard adjutsments Turn the machine pulley to align the tip of the rotary hook with the needle center line. Then loosen the set screw q and turn the eccentric shaft w to adjust so that the clearance between the needle and the rotary hook is 0.01 - 0.08 mm. 9-4. Adjusting the driver needle gurard Turn the machine pulley to align the tip of the rotary hook with the needle center line. Then loosen the set screw w and turn the eccentric shaft e to adjust so that the driver needle guard q contacts the needle. If the needle contact pressure is too great, skipped stitches may occur. On the other hand, if the driver needle guard q is not touching the needle, the tip of the inner rotary hook will obstruct the needle, resulting in an excessively high amount of friction. 9-5. Adjusting the shuttle race thread guide The needle groove of the shuttle race thread guide q should be aligned with the center of the needle plate hole, and the needle center and the angled section A should be aligned. NOTE If the shuttle race thread guide is in the wrong position, thread breakages, soiled thread or catching of the thread may occur. BAS-343E 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

9.
Standard adjutsments
33
BAS-343E
9-3. Adjusting the needle clearance
Turn the machine pulley to align the tip of the rotary hook with the needle center line.
Then loosen the set screw
q
and turn the eccentric shaft
w
to adjust so that the clearance between the needle and the rotary hook is 0.01 - 0.08
mm.
9-4. Adjusting the driver needle gurard
Turn the machine pulley to align the tip of the rotary hook with the needle center line.
Then loosen the set screw
w
and turn the eccentric shaft
e
to adjust so that the driver needle guard
q
contacts the needle.
If the needle contact
pressure is too great, skipped stitches may occur.
On the other hand, if the driver needle guard
q
is not touching the
needle, the tip of the inner rotary hook will obstruct the needle, resulting in an excessively high amount of friction.
9-5. Adjusting the shuttle race thread guide
The needle groove of the shuttle race thread guide
q
should be aligned with the center of the needle plate hole, and
the needle center and the angled section A should be aligned.
NOTE
If the shuttle race thread guide is in the wrong position, thread breakages, soiled thread or catching of the
thread may occur.
0.01 - 0.08mm