Brother International T-8752C Instruction Manual - English - Page 90

TROUBLESHOOTING, Error code, Possible cause, Problem with control box.

Page 90 highlights

14. TROUBLESHOOTING Error code E090 Treadle connector is not connected. Possible cause ・ Is the 4-pin treadle connector inside the control box disconnected? Press the power OFF switch, and then check that the 4-pin treadle connector is connected to connector P14 on the main PCB. If there is a broken wire in the cord of the treadle connector, replace the treadle unit. E091 E095 ・ The settings in "Setting method for standard depression stroke" may be incorrect. Redo the settings in "Setting method for standard depression stroke". ・ Problem with treadle unit. Replace the treadle unit. ・ Was the power ON switch pressed while the treadle was still depressed? Return the treadle to the neutral position. When the treadle neutral position is detected, the error will be cleared and normal operation will then be possible. ・ Is the power supply voltage too low? Check the power supply voltage. E111 E130 E131 Problem with motor encoder signal. ・ The sewing machine could not stop correctly at the needle up stop position after thread trimming. Remove any thread scraps that may be blocking the motor. Press the power OFF switch and then turn the machine pulley by hand and check that it turns easily. Check that there are no problems with the thread trimming mechanism. The sewing machine or motor do not operate when the treadle is depressed. ・ Is the 4-pin motor connector inside the control box disconnected? Press the power OFF switch and check the connection of the 4-pin motor connector. ・ Has the sewing machine locked up? Press the power OFF switch and then turn the machine pulley by hand and check that it turns easily. ・ Problem with control box. Replace the control box. ・ Is the 10-pin resolver connector inside the control box disconnected? Press the power OFF switch, and then check that the 10-pin resolver connector is connected to connector P6 on the main PCB. ・ Problem with motor or main PCB. Replace the motor or the control box. E132 Problem with motor operation. ・ Problem with motor. Replace the motor. ・ Problem with drive PCB. Replace the control box. E140 Motor reverse operation. ・ Motor reverse operation was detected. Replace the motor. Page * ** * ** * * * ** 12* * ** 12 81 T-8421C, 8422C, 8452C, 8722C, 8752C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

T-8421C, 8422C, 8452C, 8722C, 8752C
14. TROUBLESHOOTING
81
Error code
Possible cause
Page
E090
Treadle
connector is not
connected.
Is the 4-pin treadle connector inside the control box disconnected?
Press the power OFF switch, and then check that the 4-pin treadle connector is
connected to connector P14 on the main PCB.
If there is a broken wire in the cord of the treadle connector, replace the treadle
unit.
*
**
E091
The settings in “Setting method for standard depression stroke” may be incorrect.
Redo the settings in “Setting method for standard depression stroke”.
Problem with treadle unit.
Replace the treadle unit.
*
**
E095
Was the power ON switch pressed while the treadle was still depressed?
Return the treadle to the neutral position. When the treadle neutral position is
detected, the error will be cleared and normal operation will then be possible.
Is the power supply voltage too low?
Check the power supply voltage.
*
E111
The sewing machine could not stop correctly at the needle up stop position after
thread trimming.
Remove any thread scraps that may be blocking the motor.
Press the power OFF switch and then turn the machine pulley by hand and
check that it turns easily.
Check that there are no problems with the thread trimming mechanism.
*
*
**
E130
The sewing machine or motor do not operate when the treadle is depressed.
Is the 4-pin motor connector inside the control box disconnected?
Press the power OFF switch and check the connection of the 4-pin motor
connector.
Has the sewing machine locked up?
Press the power OFF switch and then turn the machine pulley by hand and
check that it turns easily.
Problem with control box.
Replace the control box.
12*
*
**
E131
Problem with
motor encoder
signal.
Is the 10-pin resolver connector inside the control box disconnected?
Press the power OFF switch, and then check that the 10-pin resolver connector
is connected to connector P6 on the main PCB.
Problem with motor or main PCB.
Replace the motor or the control box.
12*
**
E132
Problem with
motor operation.
Problem with motor.
Replace the motor.
Problem with drive PCB.
Replace the control box.
**
**
E140
Motor reverse
operation.
Motor reverse operation was detected.
Replace the motor.
**