Canon BJC 50 Service Manual - Page 137
Canon BJC 50 - Color Inkjet Printer Manual
View all Canon BJC 50 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
BJC-50 6.3 Signal Contacts Part 4: Technical Reference The scanner cartridge is recognized by TOP.S, DIAS and CCHK signals. The scanned image output to the printer is transmitted with a SCLOCK signal in sync with a SDATA signal. The scanner is controlled by the internal register setting signals, CMD0, 1, 2 and 3. 29 28 26 25 24 21 22 23 20 27 15 3 19 18 17 16 11 12 13 14 10 9 4 8 7 6 5 2 1 Scanner Cartridge Figure 4-35 Contact Pad Layout TABLE 4-6 LIST OF SCANNER CARTRIDGE SIGNAL CONTACTS No. 1, 2 5, 6 9 10 11 12 13 14 19 20 21 22 23 24 25 26 28 29 Signal LAMP G V LAMP TOP. S C. CHA ID0 ID1 INKS 2 Vss COM 0 (REN) COM 1 (RWR) COM 2 (RDT) COM 3 (N.C) Vdd S CLOCK (DTCK) S SYNE (LNST) S RES S DATA (DT) C. CHK Type ...IN OUT OUT OUT OUT OUT GND IN IN IN ...OUT IN IN OUT OUT Description GND for LED LED drive voltage (+24Vdc) Scanner detection GND Scanner detection OPEN Color scanner cartridge acknowledge signal Color scanner cartridge acknowledge signal IS-11/IS-12 detection GND Register enable Register write clock signal Register data signal Not used IC driver voltage (+5Vdc) Scan data transfer signal Line start signal System reset signal Scan data HScanner detection OPEN (Ref. BJ Cartridge) VHG HVH TOP DIODEA ID0 ID1 - HVss Odd ENB BENB1 BENB2 BENB3 HVdd HCLK HLATCH HRES HDATA DIODEK 4-49