Page 62 highlights
Part 3: Operating Instructions BJC-50 c) Connecting the Infrared interface When transmitting data from the computer to the printer through the built-in IrDA, beware of the following: • The printer and computer IrDA transitters should be within 1 m of each other. (Depending on the computer, infrared rays may not reach the printer's IrDA transmitter) • The printer IrDA module angle is must be within 15 degrees of the vertical and horizontal optical axis. • Scanning a 180dpi color A4 document with the optional scanner cartridge can take up to 30 minutes. The use of bidirectional centronics interface for data transmission is recommended. IrDA 15° 15° Figure 3-5 IrDA Angle of Rotation When both interface mediums, i.e. the bidirectional centronic interface and the IrDA, are connected, the printer automatically, switches over to the interface medium that first detects the computer signals. 3-4