Canon LV-7575 LV-7575 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS - Page 34
CF_CEIL Command, CF_REAR Command, CF_RCODE Command
View all Canon LV-7575 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
LV-7575 Expand Serial Command Functional Specifications 8.10.4 CF_CEIL Command Command "CF_CEIL_%1" [CR] %1 "ON Set Ceiling to ON. "OFF Set Ceiling to OFF. Details Set/Cancel Ceiling mode.(Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.10.5 CF_REAR Command Command "CF_REAR_%1" [CR] %1 "ON Set Rear to ON. "OFF Setl Rear to OFF. Details Set/Cancel Rear mode (Available only in the normal Power ON status) When Rear is ON, projected image is left/right reversed. The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.10.6 CF_RCODE Command Command "CF_RCODE_%1" [CR] "001 Select Code 1 "002 Select Code 2 "003 Select Code 3 "004 Select Code 4 %1 "005 Select Code 5 "006 Select Code 6 "007 Select Code 7 "008 Select Code 8 "UP Switch forward (Code1→Code2→Code3 - - - →Code8→Code1) "DN" --------- Switch backward (Code8→Code7→Code6 - - -→Code1→Code8) Details Select Code of Remote Control (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 34/71