Canon LV-7575 LV-7575 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS - Page 38

CF_POWER Command, CF_FREEZE Command - projector model

Page 38 highlights

LV-7575 Expand Serial Command Functional Specifications 8.11.3 CF_POWER Command Command "CF_POWER_%1" [CR] "ON Power ON "OFF Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. %1 * Error Code is returned in some projector statuses, which indicates the command is impossible to be executed. (See [8.3] for details) * Returning the response "000" [CR] (acceptable) does not always mean that the status has already changed to Power ON. Example: When the temperature approaches abnormal status after returning "000" [CR] to the command CF_POWER ON. Therefore, to get the projector status requires using Status Read command. Details Set Power to ON/OFF Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.11.4 CF_FREEZE Command Command "CF_FREEZE_%1" [CR] "ON Set Freeze to ON. "OFF Set Freeze to OFF. %1 "UP Switch forward (On→Off→On→---) "DN Switch backward (On→Off→On→---) * The same operation for "UP" and "DN" as this model has only "ON" / "OFF". Details Set / Cancel Freeze function. (Available only in the normal Power ON status) Receiving FREEZE_ON command when the projector is Freeze enabled, Freeze status is kept. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 38/71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

LV-7575 Expand Serial Command Functional Specifications
38/71
8.11.3
CF_POWER Command
Command
“CF_POWER_%1” [CR]
%1
“ON” ----------------------------- Power ON
“OFF” --------------------------- Power OFF
* Issuing another command during countdown process forced countdown
operation to be terminated.
* Error Code is returned in some projector statuses, which indicates the
command is impossible to be executed. (See [8.3] for details)
* Returning the response “000” [CR] (acceptable) does not always mean that the
status has already changed to Power ON.
Example: When the temperature approaches abnormal status after returning
“000” [CR] to the command CF_POWER ON.
Therefore, to get the projector status requires using Status Read command.
Details
Set Power to ON/OFF
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.11.4
CF_FREEZE Command
Command
“CF_FREEZE_%1” [CR]
%1
“ON” --------------------------- Set Freeze to ON.
“OFF” ------------------------- Set Freeze to OFF.
“UP” --------------------------- Switch forward (On
Off
On
---)
“DN” --------------------------- Switch backward (On
Off
On
---)
* The same operation for “UP” and “DN” as this model has only “ON” / “OFF”.
Details
Set / Cancel Freeze function.
(Available only in the normal Power ON status)
Receiving FREEZE_ON command when the projector is Freeze enabled, Freeze
status is kept.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]