Canon LV-7575 LV-7575 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS - Page 49
CR_MODELIST Command, CR_HMSLOT Command, CR_NMSLOT1 Command, CR_NMSLOT2 Command, CR_NMSLOT3 Command
View all Canon LV-7575 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
LV-7575 Expand Serial Command Functional Specifications 9.7.9 CR_MODELIST Command Command "CR_MODELIST" [CR] Details Get possible modes for Mode list Acceptable "000_%1_%2_---_%x" [CR] Error Code "101" is returned except for PC-Analog and for no signal with PC-Analog Possible modes in Mode1-10 are returned when PC-Analog signal is coming. Response %1 Unacceptable "MODE1" "MODE2" "MODE3" : : "MODE8" "MODE9" "MODE10" "Error Code" [CR] 9.7.10 CR_HMSLOT Command Command "CR_HMSLOT" [CR] Details Get the total number of Input. Acceptable "000_%1" [CR] Response %1 "004 When LV-NI02 is attached. "003 When LV-NI02 is not attached. Unacceptable "Error Code" [CR] 9.7.11 CR_NMSLOT1 Command Command "CR_NMSLOT1" [CR] Details Get terminal information of Input1 Acceptable "000_%1" [CR] Response %1 "RGB" Unacceptable "Error Code" [CR] 9.7.12 CR_NMSLOT2 Command Command "CR_NMSLOT2" [CR] Details Get terminal information of Input2 Acceptable "000_%1" [CR] Response %1 "5BNC" Unacceptable "Error Code" [CR] 9.7.13 CR_NMSLOT3 Command Command "CR_NMSLOT3" [CR] Details Get terminal information of Input3 Response Acceptable "000_%1" [CR] %1 "VIDEO" 49/71