Canon LV-7575 LV-7575 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS - Page 36
CF_P-MANETIME Command, CF_FANSPEED Command, CF_KEYDIS Command, CF_FDEFAULT Command
View all Canon LV-7575 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
LV-7575 Expand Serial Command Functional Specifications 8.10.10 CF_P-MANETIME Command Command "CF_P-MANETIME_%1" [CR] "01" - "30 Directly specify setting time by the minute "UP Increment value by 1 %1 (Switched in 01→02→ --- → 30 → 01 order) "DN Decrement value by 1 (Switched in 30→29→ --- → 01 → 30 order) Details Set time of Power Management time (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.10.11 CF_FANSPEED Command Command "CF_FANSPEED_%1" [CR] %1 "MAX Select maximum fan speed "NOR Select normal fan speed Details Switch Fan Control Speed mode.(Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.10.12 CF_KEYDIS Command Command "CF_KEYDIS_%1" [CR] "NONE RC and KEY are both enabled. %1 "RC RC is disabled. "KEY KEY is disabled. Details Disable RC and/or KEY functions (Available only in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.10.13 CF_FDEFAULT Command Command "CF_FDEFAULT_%1" [CR] %1 "RST" Details Reset to Factory Default setting (Available only in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 36/71